APAR status
Closed as program error.
Error description
The 999 generated from the compliance map is reporting incorrectly as being accepted for an input with a invalid NM1 segment for a 005010X279A1 271 transaction. The 2100A NM103 is required. The same input data when run against a validation map using the hipaa_x12.mtt, shows an input error for the segment.
Local fix
WTXCQ - WTX00037519 AR / AR Circumvention: None
Problem summary
Users affected: Websphere Transformation Extender Pack for hipaa Problem Description: 999 for 5010X279A1 transaction 271 not reporting error when NM103 is missing for loop 2100A Platforms affected: ALL
Problem conclusion
Made NM103 element in segment tree mandatory for loop 2100A Delivered in: HCIP 4.3.2.0, HCIP 4.3.2.1
Temporary fix
Comments
APAR Information
APAR number
PM38537
Reported component name
WEBSPHERE HIPAA
Reported component ID
5724M6100
Reported release
431
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2011-05-05
Closed date
2011-05-16
Last modified date
2011-09-19
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WEBSPHERE HIPAA
Fixed component ID
5724M6100
Applicable component levels
R431 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSD8","label":"IBM Transformation Extender"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.3.1","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]