IBM Support

PM36157: LAUNCHER CRASH DURING SHUTDOWN IN MPISEMDESTROY () AT MPI_SEM.CPP:87

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Launcher crash on shutdown.  Crash shows the current thread as
    #0 0xc000000013a8d490:0 in mpiSemDestroy () at mpi_sem.cpp:87
    
    This issue can only be replicated when using multiple adapters.
    

Local fix

  • WTXCQ - WTX00037257
    PB / PB
    Circumvention: Use separate Launchers where each use only one
    type of adapter
    

Problem summary

  • Users Affected:
    WebSphere Transformation Extender customers using email and http
    adapters
    
    Problem Description:
    A system running WTX email and http adapters at the same time
    may crash in the http adapter module with the following stack
    trace:
    
    Signal 11 (SIGSEGV) delivered
    mpiSemDestroy  [libs/libdstxpi.so]
    termlib + 0x140 at m4email.c:410
    StandardTerm + 0x30 at adptglue.c:641
    SSDestroyLibrary + 0x20 at adptglue.c:707
    m4http_DestroyLibrary + 0x30 at m4http.c:760
    _AdapterDestroy + 0x1c0 at rmadpt.c:650
    
    The similar crash in mpiSemDestroy is possible if only email
    adapter is used.
    The crash happens during launcher shutdown procedure.
    
    Platforms Affected:
    ALL
    

Problem conclusion

  • The problem is caused by an attempt to destroy a mutex that was
    not initialized. The code has been fixed.
    
    Delivered in:
    8.2.0.6, 8.3.0.5
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM36157

  • Reported component name

    WEBSPHERE LAUNC

  • Reported component ID

    5724M4011

  • Reported release

    830

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2011-04-04

  • Closed date

    2011-04-22

  • Last modified date

    2011-07-26

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WEBSPHERE LAUNC

  • Fixed component ID

    5724M4011

Applicable component levels

  • R820 PSY

       UP

  • R830 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSD8","label":"IBM Transformation Extender"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.3","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]