APAR status
Closed as program error.
Error description
A WTX 8.3.0.3 XML Schema Classic imported type tree, generated from an XML Schema containing an element defined with nillable=true, fails validation of an element with the format <element xsd:nil="true" />.
Local fix
WTXCQ - WTX00037060 PVB / PVB Circumvention: None
Problem summary
Users Affected: WebSphere Transformation Extender customers using classic schema importer Problem Description: Classic type tree generated in 8.3.0.3 cannot pass through nillable=true element. Platforms Affected: Windows
Problem conclusion
Correct creation of Classic type tree when element "nillable=true" option is present. Element Value needs to have Empty element information. Prevents validation error when "nillable=true" option is present in data. Delivered in: 8.2.0.6, 8.3.0.5
Temporary fix
Comments
APAR Information
APAR number
PM35852
Reported component name
WEBSPHERE DESIG
Reported component ID
5724M4008
Reported release
830
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2011-03-29
Closed date
2011-04-28
Last modified date
2011-07-26
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WEBSPHERE DESIG
Fixed component ID
5724M4008
Applicable component levels
R820 PSY
UP
R830 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSD8","label":"IBM Transformation Extender"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.3","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]