PM21690: DESIGN STUDIO OR COMMAND SERVER CRASH OCCURS WHEN RUNNING A MAP WITH A FUNCTIONAL MAP USING AN INDEX() OF A LOOKUP() FUNCTION

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • A Design Studio or Command Server crash occurs when running a
    map that calls a functional map which uses an INDEX() function
    of a LOOKUP() function.
    

Local fix

  • WTXCQ - WTX00035369
    LV / LV
    Circumvention: Use the following suggested map rule:
    
    = IF (some_object = "something", NUMBERTOTEXT (INDEX
    (some_object)))
    

Problem summary

  • Users Affected:
    WebSphere Transformation Extender customers using INDEX function
    
    Problem Description:
    Map crashing in both Design Studio and Command Server when a
    particular functional map is called.
    
    Platforms Affected:
    All
    

Problem conclusion

  • Map was using INDEX incorrectly, we can only INDEX a type (not
    a LOOKUP).  The INDEX function has been modified so it will not
    cause the crash, but neither will it not work.
    
    Delivered in:
    8.3.0.3, 8.2.0.6, 8.1.0.6
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM21690

  • Reported component name

    WEBSPHERE LAUNC

  • Reported component ID

    5724M4011

  • Reported release

    830

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2010-09-01

  • Closed date

    2010-09-03

  • Last modified date

    2010-09-23

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WEBSPHERE LAUNC

  • Fixed component ID

    5724M4011

Applicable component levels

  • R810 PSY

       UP

  • R820 PSY

       UP

  • R830 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSD8","label":"IBM Transformation Extender"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.3","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date:
23 September 2010