  • Closed as program error.

Error description

  • The WTX version 8.3 DB2 Database Adapter trace file (.dbl)
    contains entries for each insert that was performed. This is
    different from the DB2 Database Adapter trace entries in
    previous releases of WTX.
    
    Sample output:
    
    <1234-7890>: The columns are of the following types:
    <1234-7890>: Column 1 (FIELD1) type is VARCHAR, precision is 5.
    <1234-7890>: Column 2 (FIELD2) type is VARCHAR, precision is 5.
    <1234-7890>: Column 3 (FIELD3) type is VARCHAR, precision is 5.
    <1234-7890>: Column 4 (FIELD4) type is VARCHAR, precision is 5.
    <1234-7890>: Column 5 (FIELD5) type is VARCHAR, precision is 5.
    <1234-7890>: The insert statement to be executed is:
    <1234-7890>: INSERT INTO test_table  VALUES (?,?,?,?,?)
    <1234-7890>: INSERT INTO test_table  VALUES (?,?,?,?,?)
    <1234-7890>: Column: FIELD1
    <1234-7890>: Column: FIELD2
    <1234-7890>: Column: FIELD3
    <1234-7890>: Column: FIELD4
    <1234-7890>: Column: FIELD5
    <1234-7890>: Inserted 1 rows.
    <1234-7890>: Column: FIELD1
    <1234-7890>: Column: FIELD2
    <1234-7890>: Column: FIELD3
    <1234-7890>: Column: FIELD4
    <1234-7890>: Column: FIELD5
    <1234-7890>: Inserted 2 rows.
    <1234-7890>: Column: FIELD1
    <1234-7890>: Column: FIELD2
    <1234-7890>: Column: FIELD3
    <1234-7890>: Column: FIELD4
    <1234-7890>: Column: FIELD5
    <1234-7890>: Inserted 3 rows.
    <1234-7890>: Column: FIELD1
    <1234-7890>: Column: FIELD2
    <1234-7890>: Column: FIELD3
    <1234-7890>: Column: FIELD4
    <1234-7890>: Column: FIELD5
    <1234-7890>: Inserted 4 rows.
    

Local fix

  • WTXCQ - WTX00035134
    CH / CH
    Circumvention: None
    

Problem summary

  • WebSphere Transformation Extender DB2 adapter customers that are
    submitting multiple data rows for table or stored procedure
    insertion will notice extraneous trace file information for each
    successful insert operation.
    
    Problem Description:
    Redundant trace information appears in the WTX database adapter
    trace file.
    
    Platforms Affected:
    All
    

Problem conclusion

  • Redundant column information was removed from the trace file,
    especially during multiple executions of the same stored
    procedure.  Also, completion results for each individual row
    that was successfully inserted has been removed, which is all
    consistent with prior releases of the WTX database adapter trace
    file.
    
    Delivered in:
    8.3.0.3
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM19286

  • Reported component name

    WTX FOR INT SER

  • Reported component ID

    5724M4010

  • Reported release

    820

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2010-07-27

  • Closed date

    2010-08-06

  • Last modified date

    2010-09-15

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WTX FOR INT SER

  • Fixed component ID

    5724M4010

Applicable component levels

  • R830 PSY

       UP

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCKRDT","label":"WTX for Integration Servers"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.2","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
15 September 2010