APAR status
Closed as program error.
Error description
In the 837 transactions, the AMT*D segment is required in the 2320 loop when the payer has adjudicated in that 2320 loop has adjudicated the claim. Claims are passing compliance when the 2320 loop contains the CAS segment and there is no 2320 AMT*D. In the 2320 loop the CAS segment is an indication that the payer has adjudicated the claim. This applies to the 837I, 837D, and 837P.
Local fix
JK/JK ITXCQ - ITX00059921 Circumvention: None
Problem summary
Users affected: Transformation Extender pack for Healthcare Payer HIPAA Problem Description: Claims are passing compliance when the 2320 loop contains the CAS segment and there is no 2320 AMT*D. Platforms affected: ALL
Problem conclusion
Problem Conclusion: New rules added - 59113, 59114, 59115 - 2320 AMT="D" must be present when 2320 CAS present for 837P, 837I, and 837D. These are disabled by default in the qualifier.dat file. Applies to: Healthcare Payer 9.0.2, 10.0 Fixed in the next Service Pack and releases. To obtain the fix for this APAR: to see if the next service pack or product release is available, check the IBM Transformation Extender Release Notes page: http://www.ibm.com/support/docview.wss?uid=swg27008337 If the service pack or product release is available, download it from Fix Central: http://www.ibm.com/support/fixcentral If the service pack or product release is not available and you require the APAR fix immediately, request a Limited Availability Interim Fix (LAIF) by opening a PMR: http://www.ibm.com/mysupport Prior to version 9.0.0, IBM Transformation Extender was called IBM WebSphere Transformation Extender.
Temporary fix
Comments
APAR Information
APAR number
PH15995
Reported component name
TX HIPPA EDI
Reported component ID
5724M6100
Reported release
901
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-08-22
Closed date
2019-09-30
Last modified date
2019-09-30
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TX HIPPA EDI
Fixed component ID
5724M6100
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSD8","label":"IBM Transformation Extender"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"901","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date:
30 September 2019