  • In some circumstances such as the select value of the
    xsl:analyze-string or the value of a literal attribute when
    specified as an attribute value template where the expression
    results in a seqeuence of more than one item, the processor will
    fail to discard the extra items in backwards compatibility
    mode.  This may result in an error ( XPTY0004 ) as in the case
    of xsl:analyze-string or in the processor concatenating the
    string values of all the items in the sequence together as in
    the case of the value of a literal attribute.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:  All users of the IBM WebSphere Application  *
    *                  Server v7.0 Feature Pack for XML 1.0.       *
    ****************************************************************
    * PROBLEM DESCRIPTION: Failure to convert a sequence to a      *
    *                      singleton in backwards compatibility    *
    *                      mode may result in an error or          *
    *                      incorrect output.                       *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    In some circumstances such as the select value of the
    xsl:analyze-string or the value of a literal attribute when
    specified as an attribute value template where the expression
    results in a sequence of more than one item, the processor will
    fail to discard the extra items in backwards compatibility
    mode.  This may result in an error ( XPTY0004 ) as in the case
    of xsl:analyze-string or in the processor concatenating the
    string values of all the items in the sequence together as in
    the case of the value of a literal attribute.
    

Problem conclusion

  • Code is now being generated in backwards compatibility mode
    that will convert the sequence to a singleton in the described
    circumstances.
    
    The fix for this APAR is currently targeted for inclusion in
    fix pack 1.0.0.3. Please refer to the Recommended Updates
    page for delivery information:
    http://www.ibm.com/support/docview.wss?rs=180&uid=swg27004980
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM08120

  • Reported component name

    XML FEATUREPACK

  • Reported component ID

    5724J0856

  • Reported release

    700

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-02-19

  • Closed date

    2010-03-03

  • Last modified date

    2010-03-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    XML FEATUREPACK

  • Fixed component ID

    5724J0856

Applicable component levels

  • R700 PSY

       UP

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SUPPORT","label":"IBM Worldwide Support"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
09 February 2022