APAR status
Closed as program error.
Error description
After installing GSKit 7.0.3.20 on Windows, ikeyman.bat as supplied with IBM HTTP Server no longer works.
Local fix
Use a locally modified ikeyman.bat such as the following, updating the setting of JAVA_HOME and the GSKit install directory as appropriate: @echo off set JAVA_HOME=d:\IHS6029GA\_jvm c: cd "C:\Program Files\ibm\gsk7\bin" gsk7ikm.exe
Problem summary
A change in GSKit 7.0.3.20 introduced a problem where the gsk7ikm.exe program cannot locate the GSKit libraries unless gsk7ikm.exe is run from the GSKit bin directory. This problem only affects ikeyman users on the Windows platform.
Problem conclusion
The ikeyman.bat batch file provided with IBM HTTP Server will be modified to work with GSKit 7.0.3.20 or with any subsequent levels of GSKit. It will no longer run gsk7ikm.exe but instead will invoke the GSKit classes for ikeyman directly.
Temporary fix
Comments
APAR Information
APAR number
PK23962
Reported component name
IBM HTTP SERVER
Reported component ID
5724J0801
Reported release
60W
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2006-04-25
Closed date
2006-04-25
Last modified date
2006-06-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IKEYMAN
Fix information
Fixed component name
IBM HTTP SERVER
Fixed component ID
5724J0801
Applicable component levels
R60W PSN