IV73158: WEBSPHERE MQ QUEUE MANAGER ENDS. FDC IS CREATED WITH PROBE ID ZT160001

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • This APAR is to backport APAR IV34170 to MQ version 7.0.1.
    .
    WebSphere MQ queue manager ends. FDC is created with Probe ID
    ZT160001 reporting "Timed-out waiting for process manager to
    start".
    The FDC indicates an attempted restart of the utility manager
    process during endmqm fails.
    
    WebSphere MQ First Failure Symptom Report
    =========================================
    Probe Id :- ZT160001
    Component :- zusStartManager
    Major Errorcode :- xecX_W_DAEMON_UNAVAILABLE
    Probe Description :- AMQ6125: An internal WebSphere MQ error
    has occurred.
    Comment1 :- Timed-out waiting for process manager to
    start.
    ----------------------------------------------------------------
    MQM Function Stack
    zusQueryAncillaryProcess
    zusConnectToProcessManager
    zusStartManager
    xcsFFST
    

Local fix

  • NA
    

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    You may encounter this issue during endmqm if the queue manager
    process manager had previously ended due to some issue with the
    process manager (which would normally itself be reported via one
    or more FDCs). The probe ZT160001 FDC can be ignored.
    
    
    Platforms affected:
    MultiPlatform
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    The endmqm process was attempting to restart the process manager
    if connection could not be established with it. The restart
    attempt could fail, leading to the probe ZT160001 FDC.
    

Problem conclusion

  • The endmqm process should not be attempting to restart the
    process manager, and it has now been stopped from doing that.
    
    ---------------------------------------------------------------
    The fix is targeted for delivery in the following PTFs:
    
    Version    Maintenance Level
    v7.0       7.0.1.14
    
    The latest available maintenance can be obtained from
    'WebSphere MQ Recommended Fixes'
    http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006037
    
    If the maintenance level is not yet available information on
    its planned availability can be found in 'WebSphere MQ
    Planned Maintenance Release Dates'
    http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006309
    ---------------------------------------------------------------
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV73158

  • Reported component name

    WMQ LIN X86 V7

  • Reported component ID

    5724H7224

  • Reported release

    701

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2015-05-11

  • Closed date

    2015-07-29

  • Last modified date

    2015-07-29

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WMQ LIN X86 V7

  • Fixed component ID

    5724H7224

Applicable component levels

[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSFKSJ","label":"WebSphere MQ"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.0.1"}]

Document Information

Modified date: