IBM Support

IV10040: THE WMQ RESOURCE ADAPTER'S META-INF/RA.XML FILE LISTS SOME ADMINISTRATIVE PROPERTIES UNDER AN INCORRECT JMS OBJECT TYPE

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Some administrative properties listed in the WebSphere MQ
    Resource Adapter wmq.jmsra.rar's META-INF/ra.xml file are not
    associated with the appropriate object type.
    
    For example, the putAsyncAllowed property is listed under
    connection factories when it is actually a destination property.
    

Local fix

  • To set one of the misplaced properties on a JMS object, add the
    arbitraryProperties property to the object definition.  This
    property accepts a comma-separated list of name="value" pairs,
    for example:
    .
      readAheadAllowed="1",putAsyncAllowed="1"
    

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    This issue affects users of the v7.0 and v7.1 WebSphere MQ
    Resource Adapter.
    
    Platforms affected:
    All Distributed (iSeries, all Unix and Windows) +Java
    ****************************************************************
    PROBLEM SUMMARY:
    The JEE Connector Architecture (JCA) outbound interfaces in the
    WebSphere MQ Resource Adapter are described using a ra.xml file
    within the resource adapter archive file. This file listed some
    JMS destination properties as connection factory properties,
    such as putAsyncAllowed.
    
    It was therefore not possible to set these properties on the
    destination objects.
    

Problem conclusion

  • The putAsyncAllowed and readAheadAllowed properties have been
    added to the JMS destination parameters.
    
    The JMS destination properties defined as connection factory
    parameters have been left unchanged, as removing parameters may
    cause application servers to report an error. Setting these
    destination properties on the connection factory has no effect.
    
    The connectionNameList property was added to the connection
    factory parameters.
    
    In addition, it was observed that while the Activation
    Specifications permitted 'readAheadAllowed' and
    'readAheadClosePolicy' to be set, this had no effect. This
    APAR also corrects this behavior.
    
    ---------------------------------------------------------------
    The fix is targeted for delivery in the following PTFs:
    
                       v7.0
    Platform           Fix Pack 7.0.1.8
    --------           --------------------
    Windows            U200335
    AIX                U845856
    HP-UX (PA-RISC)    U847965
    HP-UX (Itanium)    U847970
    Solaris (SPARC)    U847966
    Solaris (x86-64)   U847972
    iSeries            7.0.1.8
    Linux (x86)        U847967
    Linux (x86-64)     U847971
    Linux (zSeries)    U847968
    Linux (Power)      U847969
    
                       v7.1
    Platform           Fix Pack 7.1.0.1
    --------           --------------------
    Windows            7.1.0.1
    AIX                7.1.0.1
    HP-UX (PA-RISC)    7.1.0.1
    HP-UX (Itanium)    7.1.0.1
    Solaris (SPARC)    7.1.0.1
    Solaris (x86-64)   7.1.0.1
    iSeries            7.1.0.1
    Linux (x86)        7.1.0.1
    Linux (x86-64)     7.1.0.1
    Linux (zSeries)    7.1.0.1
    Linux (Power)      7.1.0.1
    
    The latest available maintenance can be obtained from
    'WebSphere MQ Recommended Fixes'
    http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006037
    
    If the maintenance level is not yet available information on
    its planned availability can be found in 'WebSphere MQ
    Planned Maintenance Release Dates'
    http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006309
    ---------------------------------------------------------------
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV10040

  • Reported component name

    WMQ AIX V7

  • Reported component ID

    5724H7221

  • Reported release

    701

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-11-01

  • Closed date

    2011-11-30

  • Last modified date

    2012-01-16

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WMQ AIX V7

  • Fixed component ID

    5724H7221

Applicable component levels

  • R701 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSDEZSF","label":"IBM WebSphere MQ Managed File Transfer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.0.1","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date: