IBM Support

IT18756: mqcertck fails to load GSKit library with probid CO558200 when running from runmqras

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • mqcertck tool fails to load gskit library when running from
    runmqras and generates the following Failure Data Capture (FDC)
    record:
    
    WebSphere MQ First Failure Symptom Report
    
    =========================================
    LVLS              :- 8.0.0.4
    Product Long Name :- WebSphere MQ for AIX
    Vendor            :- IBM
    Data Path         :- /var/mqm
    Installation Path :- /usr/mqm
    Probe Id          :- CO558200
    Application Name  :- MQM
    Component         :- ccigsk_load
    Effective UserID  :- 213 (mqm)
    Real UserID       :- 213 (mqm)
    Program Name      :- mqcertck
    Major Errorcode   :- STOP
    Minor Errorcode   :- OK
    Probe Type        :- HALT6109
    Probe Severity    :- 1
    Probe Description :- AMQ6109: An internal WebSphere MQ error
    has occurred.
    FDCSequenceNumber :- 0
    Arith1            :- 2 (0x2)
    Arith2            :- 536908320 (0x20009220)
    Comment1          :- GSKit library load failed
    
    MQM Function Stack
    ccigsk_load
    xcsFFST
    
    ...
    -} xcsLoadFunction rc=xecU_S_LOAD_FAILED
    -{ rrxError
    -} rrxError rc=rrcE_NO_COMMS_LIBRARY
    -{ xcsBuildDumpPtr
    --{ xcsGetMemFn
    --} xcsGetMemFn rc=OK
    -} xcsBuildDumpPtr rc=OK
    -{ xcsFFST
    

Local fix

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    Users using runmqras on a system with more than one gskit
    installations(likely one global and one or more local
    installations).
    
    
    Platforms affected:
    AIX
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    This problem occurred because LIBPATH for gskit was not
    correctly set if the system had more than one gskit
    installations.
    

Problem conclusion

  • runmqras has been modified to correctly set the LIBPATH before
    running gskit command.
    
    ---------------------------------------------------------------
    The fix is targeted for delivery in the following PTFs:
    
    Version    Maintenance Level
    v8.0       8.0.0.7
    v9.0 CD    9.0.2
    v9.0 LTS   9.0.0.1
    
    The latest available maintenance can be obtained from
    'WebSphere MQ Recommended Fixes'
    http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006037
    
    If the maintenance level is not yet available information on
    its planned availability can be found in 'WebSphere MQ
    Planned Maintenance Release Dates'
    http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006309
    ---------------------------------------------------------------
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT18756

  • Reported component name

    WMQ BASE MULTIP

  • Reported component ID

    5724H7251

  • Reported release

    800

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-01-11

  • Closed date

    2017-01-17

  • Last modified date

    2017-06-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WMQ BASE MULTIP

  • Fixed component ID

    5724H7251

Applicable component levels