Error description

  • Can recreate the problem with simplifed job with
    seq->transfomer ->(two outputs)
    Transformer with 2 output links.
    An
    If Then Else statement derivation in 2nd output link is
    generating incorrect result.
    The derivation is:
    IF lnk_sum_out.RCMP_ALL_NOTE_CT=1 then setnull() else
    DecimaltoDecimal(lnk_sum_out.RCMP_ALL_NOTE_CT)
    it returns null when is should return
    lnk_sum_out.RCMP_ALL_NOTE_CT.
     It does not appear to go into the if statement at all so it is
    not returning null because of the setnull() function.
    When the setnull() is replaced with a constant integer for
    testing purposes and it still returns null.
    The error is coming in cases where some of the columns are
    Null. Some transformer local null variables are being reused in
    another link without resetting them.
    

Local fix

  • N/A
    

Problem summary

  • TRANSFORMER DERIVATIONS GENERATES INCORRECT RESULTS WHEN
    COLUMNS ARE NULL
    Can recreate the problem with simplifed job with
    seq->transfomer ->(two outputs)
    The error is coming in cases where some of the columns are
    Null. Some transformer local null variables are being reused in
    another link without resetting them.
    

Problem conclusion

  • Patches are available which solver the problem.
    

Temporary fix

Comments

APAR Information

  • APAR number

    JR57226

  • Reported component name

    WIS DATASTAGE

  • Reported component ID

    5724Q36DS

  • Reported release

    B30

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-01-05

  • Closed date

    2017-04-17

  • Last modified date

    2017-04-17

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WIS DATASTAGE

  • Fixed component ID

    5724Q36DS

Applicable component levels

  • RB50 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSEF","label":"IBM InfoSphere DataStage"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"11.3","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
17 April 2017