IBM Support

JR55014: MULTI-INSTANCE SEQUENCER JOB GETS ERRORS WHEN TRYING TO RESTART THE INSTANCE

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Ø
    Multi-instance sequencer job gets errors when trying to restart
    the instance
    
    "Error: Invocation Id '<id>' already exists and is not in a
    runnable state. The job <job name> is either currently
    executing, or it needs resetting."
    

Local fix

  • Use command line dsjob
    

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    The problem impacts users attempting to restart multi-instance
    jobs from the director when the job has been stopped.
    ****************************************************************
    PROBLEM DESCRIPTION:
    When selecting a job with an instance ID from the director
    it cannot be restarted if the job had been stopped. An error
    message is produced.
    ****************************************************************
    RECOMMENDATION:
    Apply patch JR55014
    ****************************************************************
    

Problem conclusion

  • Removed an erroneous restriction that resulted in an error if a
    run is commenced for a stopped multi-instance job.
    

Temporary fix

Comments

APAR Information

  • APAR number

    JR55014

  • Reported component name

    INFO SRVR PLATF

  • Reported component ID

    5724Q3612

  • Reported release

    B30

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2015-12-21

  • Closed date

    2016-01-19

  • Last modified date

    2016-01-19

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    INFO SRVR PLATF

  • Fixed component ID

    5724Q3612

Applicable component levels

  • R850 PSY

       UP

  • RB30 PSY

       UP

  • RB31 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSZJPZ","label":"InfoSphere Information Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"11.3","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
17 October 2021