JR54767: SEQUENCE JOB FAILS TO COMPILE IF USERVARIABLES STAGE CONTAINS AN EXPRESSION WITH "DS_JOB_NAME" IN IT.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The compilation of the job fails with:
    WARNING: Variable 'abc' never assigned a value.
    
    In the job in Parameter stage > User variables > Filter there
    is some Expression specified. When in this expression
    DS_JOB_NAME is specified with uppercase the job's compilation
    fails, but when changed it to ds_job_name (lowercase) the job
    compiles successfully.
    

Local fix

  • Use lowercases.
    

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    This problem only affects users who have utilised the internal
    macro names in certain expression fields with sequence jobs.
    The customers case in point was the use of DS_JOB_NAME in the
    derivation of a UserVariable setting.
    ****************************************************************
    PROBLEM DESCRIPTION:
    The problem was caused by the cumulative registration of
    context information as sequence generation progressed
    associated with internal macro names which were too simple.
    ****************************************************************
    RECOMMENDATION:
    Apply the patch for JR54767.
    ****************************************************************
    

Problem conclusion

  • The sequence generation code was modified to unregister context
    information when starting a new context. In addition the macro
    names were further obfuscated to make them significantly less
    likely. Instead of being of the form '_. . .' the were changed
    to '_&*. . .'.
    

Temporary fix

Comments

APAR Information

  • APAR number

    JR54767

  • Reported component name

    WIS DATASTAGE

  • Reported component ID

    5724Q36DS

  • Reported release

    912

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2015-11-19

  • Closed date

    2015-12-09

  • Last modified date

    2015-12-09

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WIS DATASTAGE

  • Fixed component ID

    5724Q36DS

Applicable component levels

  • R910 PSY

       UP

  • R912 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSEF","label":"InfoSphere DataStage"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"912","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
13 October 2021