Fixes are available
InfoSphere Information Server, Version 11.5 for Linux
InfoSphere Information Server, Version 11.5 for Windows
InfoSphere Information Server, Version 11.5.0.2 for Linux
InfoSphere Information Server, Version 11.5.0.2 for AIX
InfoSphere Information Server, Version 11.5.0.2 for Windows
InfoSphere Information Server, Version 11.5.0.1 for AIX
APAR status
Closed as program error.
Error description
Oracle Connector does NOT Bulk Load on Child Table when there are constraints on Parent Table. We will introduce a new environment variable (job property) called CC_ORA_DISABLE_CONSTRAINTS_BEFORE_TRUNCATE. The variable will work like this. If all 4 of these predicates are satisfied: a) Table Action is TRUNCATE, and b) Disable Constraints is YES, and c) Write mode is BULK LOAD, and d) CC_ORA_DISABLE_CONSTRAINTS_BEFORE_TRUNCATE=TRUE we will disable the constraints before truncating the table.
Local fix
Manually disable constraints on the Parent table using Before SQL and re-enable constraints on the Parent table after Bulk loading on Child Table using After SQL statements.
Problem summary
Oracle Connector does NOT Bulk Load on Child Table when there are constraints on Parent Table.
Problem conclusion
We have introduced a new environment variable (job property) called CC_ORA_DISABLE_CONSTRAINTS_BEFORE_TRUNCATE. The variable works like this. If all 4 of these predicates are satisfied: a) Table Action is TRUNCATE, and b) Disable Constraints is YES, and c) Write mode is BULK LOAD, and d) CC_ORA_DISABLE_CONSTRAINTS_BEFORE_TRUNCATE=TRUE the constraints will be disabled before truncating the table.
Temporary fix
Manually disable constraints on the Parent table using Before SQL and re-enable constraints on the Parent table after Bulk loading on Child Table using After SQL statements.
Comments
APAR Information
APAR number
JR52898
Reported component name
WIS DATASTAGE
Reported component ID
5724Q36DS
Reported release
912
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2015-03-24
Closed date
2015-05-05
Last modified date
2015-05-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WIS DATASTAGE
Fixed component ID
5724Q36DS
Applicable component levels
R910 PSY
UP
R912 PSY
UP
RB30 PSY
UP
RB31 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSEF","label":"InfoSphere DataStage"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"912","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
14 October 2021