APAR status
Closed as program error.
Error description
When using a sequential file stage which has a reject stage fails with this error message: A schema must be set in APT_FileExportOperator before use. Please note this is only a problem when using a filter option in the parallel sequential file stage.
Local fix
take out the filter option.
Problem summary
**************************************************************** USERS AFFECTED: Use of Sequential File reject link with Filter property enabled gives error at run-time. **************************************************************** PROBLEM DESCRIPTION: When using the Sequential File stage that contains a reject link, and the "Filter" property has also been applied, this leads to an error at run-time: A schema must be set in APT_FileExportOperator before use. **************************************************************** RECOMMENDATION: Apply APAR JR51986 ****************************************************************
Problem conclusion
Apply APAR JR51986
Temporary fix
N/A
Comments
APAR Information
APAR number
JR51986
Reported component name
WIS DATASTAGE
Reported component ID
5724Q36DS
Reported release
912
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-12-08
Closed date
2015-01-06
Last modified date
2015-01-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WIS DATASTAGE
Fixed component ID
5724Q36DS
Applicable component levels
R910 PSY
UP
R912 PSY
UP
RB30 PSY
UP
RB31 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSEF","label":"IBM InfoSphere DataStage"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"912","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
06 January 2015