JR51691: PARALLEL JOBS RUNNING ON WINDOWS REPORT FATAL IOPORT ERRORS

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • This problem happens on Information Server 9.1 and later on
    Windows
    systems only.  This is an intermittent failure. Parallel jobs
    will  have  this fatal message in the log:
    APT_IOPort::readBlkVirt: read for block header, partition 0, [fd
    4], returned -1 with errno 10,054 (Unknown error)
    Even though the error is listed as FATAL, the job does not
    abort.
    
    
     APAR JR51661 was created to force a job failure
    when the failure occurred. This APAR covers the root cause of
    the IO error.
    

Local fix

Problem summary

  • ERROR DESCRIPTION:
    This problem happens on Information Server 9.1 and later on
    Windows
    systems only.  This is an intermittent failure. Parallel jobs
    will  have  this fatal message in the log:
    APT_IOPort::readBlkVirt: read for block header, partition 0, [fd
    4], returned -1 with errno 10,054 (Unknown error)
    Even though the error is listed as FATAL, the job does not
    abort.
    
    
     APAR JR51661 was created to force a job failure
    when the failure occurred. This APAR covers the root cause of
    the IO error.
    
    LOCAL FIX:
    none
    

Problem conclusion

  • A patch is available which fixes the problem in the IO Code.
    However, similar error messages  have been reported which may
    not be related to IO issues.
    

Temporary fix

Comments

APAR Information

  • APAR number

    JR51691

  • Reported component name

    WIS DATASTAGE

  • Reported component ID

    5724Q36DS

  • Reported release

    912

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-11-05

  • Closed date

    2015-06-01

  • Last modified date

    2015-06-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WIS DATASTAGE

  • Fixed component ID

    5724Q36DS

Applicable component levels

  • R910 PSY

       UP

  • R912 PSY

       UP

  • RB31 PSY

       UP