APAR status
Closed as program error.
Error description
A server job which puts data using FTP plug-in stage aborted as the FTP PUT operation failed due to the disk full error at the target machine, but there appeared no FATAL error in the DataStage job log, only a WARNing "Abnormal termination of stage <JobName>..<Tranformer> detected" reported.
Local fix
Use parallel job with FTP plugin or FTP Enterprise stage.
Problem summary
FTP plugin aborts immediately when write to remote machine fails
Problem conclusion
FTP Plugin will ignore SIGPIPE signal and handle network send failure. SIGPIPE signal will be restored at end of job.
Temporary fix
Comments
APAR Information
APAR number
JR44230
Reported component name
WIS DATASTAGE
Reported component ID
5724Q36DS
Reported release
850
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / Serviceability
Submitted date
2012-09-26
Closed date
2012-10-24
Last modified date
2012-10-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WIS DATASTAGE
Fixed component ID
5724Q36DS
Applicable component levels
R850 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSEF","label":"IBM InfoSphere DataStage"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.5","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]