APAR status
Closed as program error.
Error description
FastTrack 8.1.2.5 Lookup filter rule does not refresh when navigating between columns.
Local fix
Restart for Fasttrack restored to the correct mapping specification
Problem summary
This is an issue with Lookup Filter Rule. When a column with no Lookup Filter Rule is selected initially, it shows the rule part correctly as blank. But when it is selected again after selecting a column with valid Lookup Filter Rule, it still shows the Lookup Rule of the previous column without refreshing to empty Rule.
Problem conclusion
Patch patch_JR42753_FT_all_8125.zip is provided to resolve the issue.
Temporary fix
Comments
APAR Information
APAR number
JR42753
Reported component name
INFO SRVR FASTT
Reported component ID
5724Q36FT
Reported release
810
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-05-09
Closed date
2012-05-22
Last modified date
2012-08-28
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
INFO SRVR FASTT
Fixed component ID
5724Q36FT
Applicable component levels
R812 PSY
UP
R850 PSY
UP
R870 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud \u0026 Data Platform"},"Product":{"code":"SSX3EG","label":"InfoSphere FastTrack"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.1"}]
Document Information
Modified date:
12 October 2021