  • Closed as program error.

Error description

  • While using the IBM DB2 Native driver with ODBC EE stage, in
    upsert/insert only with a reject link, the following problems
    are encountered:
    1) Performance is low compared to the same job run using the
    DataDirect DB2 Wire Protocol driver
    2) Duplicate rows are getting inserted when the table doesn't
    have a unique key constraint / warnings are issued
    

Local fix

  • N/A
    

Problem summary

  • ODBC Enterprise Upsert/Insert only with reject link jobs show
    the following two problems while using IBM DB2 Native driver.
    1) Duplicate rows will get inserted if the table doesn't contain
    unique / primary key constraint
    2) The performance of the upsert/insert only with reject link
    jobs is very slow when compared with the performance of the same
    job using the DataDirect DB2 Wire Protocol driver.
    

Problem conclusion

  • Code has been corrected to turn off atomic operations at the DB2
    side when the upsert/insert only with reject jobs use the IBM
    DB2 Native driver.
    

Temporary fix

Comments

APAR Information

  • APAR number

    JR42086

  • Reported component name

    WIS DATASTAGE

  • Reported component ID

    5724Q36DS

  • Reported release

    801

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-02-28

  • Closed date

    2012-03-16

  • Last modified date

    2012-03-16

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WIS DATASTAGE

  • Fixed component ID

    5724Q36DS

Applicable component levels

  • R753 PSY

       UP

  • R800 PSY

       UP

  • R801 PSY

       UP

  • R802 PSY

       UP

  • R810 PSY

       UP

  • R850 PSY

       UP

  • R870 PSY

       UP