IBM Support

JR41948: CERTAIN MATCH COMMANDS ARE YIELDING A WEIGHT SCORE THAT IS BELOW THE DEFAULT DISAGREEMENT WEIGHT.

 

APAR status

  • Closed as program error.

Error description

  • Certain Match commands are yielding a weight score that is below
    the default disagreement weight.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    Users of the Match stage with TIME, DELTA_PERCENT and
    PRORATED commands
    ****************************************************************
    PROBLEM DESCRIPTION:
    The handling of match default disagreement weight is wrong for
    some match commands.  For this sample Match command:
    
    MATCH1 DELTA_PERCENT DURATIO DURATIO 0.9 0.01 10
    
    if A_DURATIO="47" and B_DURATIO="30", the weight score will be
    -43.94 from our DELTA_PERCENT algorithm, but there is supposed
    to be an additional condition: if (wgt <  DisWgt) wgt =  DisWgt;
    the default disagreement weight would be -3.30 for this test
    case instead of -43.94
    
    The error only applies to the TIME, DELTA_PERCENT and PRORATED
    match commands.
     ***************************************************************
    *
    RECOMMENDATION:
    Use the patch for JR41948.
    ****************************************************************
    

Problem conclusion

  • Corrected the derfault disagreement weitgh alogorithm for the
    TIME, DELTA_PERCENT and PRORATED commands.
    

Temporary fix

Comments

APAR Information

  • APAR number

    JR41948

  • Reported component name

    WIS QUALITYSTAG

  • Reported component ID

    5724Q36QS

  • Reported release

    850

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-02-16

  • Closed date

    2012-03-09

  • Last modified date

    2012-03-09

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • Match
    

Fix information

  • Fixed component name

    WIS QUALITYSTAG

  • Fixed component ID

    5724Q36QS

Applicable component levels

  • R850 PSY

       UP

  • R870 PSY

       UP