IBM Support

JR41944: ENHANCEMENTS ADDED IN DATASTAGE 7.5 TO ADD OPERATOR IDENTIFICATI ON DETAILS TO PARALLEL PROCESS DESCRIPTIONS ARE MISSING IN 8.5.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • In DataStage 7.5, enhancement patches 72959 and 75336 were
    provided to add additional operator identification details to
    the process descriptions (viewable with ps -ef command) for
    parallel job processes.  For example:
      dsadm  8132 13.0  3.4 parallel p_acxReader_reader in
      CDI_Std_Parallel_Reader
    However, these changes were not included in the Information
    server 8.x releases where the equivalent process appears with
    description:
      dsadm  1097 18.1  0.6 /mnt/Phase_7/datastage/oem/bin/osh -
      APT_PMsectionLeaderFlag vm11012 10001 0 300 vm11012_01 vm11012
      1323449106.732142.435
    

Local fix

Problem summary

  • PROBLEM:
    ps output format changed from 751 to 85, operator name missing
    in the ps output.
    
    RESOLUTION:
    Modified the ps output format to have operator name appended to
    the existing
    ps output while the job runs.
    The ps output now includes the following as a last argument, and
    the argument
    length is limited to 50 characters:
    "parallel <operator name>"
    or
    "sequential <operator name>"
    or
    "ORCHESTRATE_Section_Leader"
    
    The environment variable APT_NO_OP_PSOUTPUT is provided to turn
    off this feature.
    APT_NO_OP_PSOUTPUT should be set in order to turn off this
    feature.
    

Problem conclusion

  • This change is  a re-implementation of what was originally a
    customer special fix. For this reason it is only available on
    Linux.
    

Temporary fix

Comments

APAR Information

  • APAR number

    JR41944

  • Reported component name

    WIS DATASTAGE

  • Reported component ID

    5724Q36DS

  • Reported release

    850

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-02-15

  • Closed date

    2012-08-15

  • Last modified date

    2012-08-15

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WIS DATASTAGE

  • Fixed component ID

    5724Q36DS

Applicable component levels

  • R850 PSY

       UP

  • R870 PSY

       UP

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSEF","label":"InfoSphere DataStage"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.5"}]

Document Information

Modified date:
07 October 2021