IBM Support

JR39315: Rule variable values are limited to the Maximum Integer value (214783647)

 

APAR status

  • Closed as program error.

Error description

  • Data Quality: Rule Logic Reference Data has a maximum value of
    214783647
    

Local fix

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    Users of Information Analyzer 8.1.2 and 8.5
    ****************************************************************
    PROBLEM DESCRIPTION:
    Rule variable values are limited to Maximum Integer value.
    ****************************************************************
    RECOMMENDATION:
    Upgrade to Information Analyzer 8.1.2 Fix Pack 6 when available,
    or 8.5 Fix Pack 2, or 8.7.
    ****************************************************************
    

Problem conclusion

  • Value was being stored in an Integer, changed to BigInt.
    

Temporary fix

Comments

APAR Information

  • APAR number

    JR39315

  • Reported component name

    WIS INFORM ANAL

  • Reported component ID

    5724Q36IA

  • Reported release

    810

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-04-01

  • Closed date

    2011-06-22

  • Last modified date

    2012-01-20

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WIS INFORM ANAL

  • Fixed component ID

    5724Q36IA

Applicable component levels

  • R812 PSY

       UP

  • R850 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud \u0026 Data Platform"},"Product":{"code":"SSZJLG","label":"InfoSphere Information Analyzer"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.1"}]

Document Information

Modified date: