IBM Support

JR39064: ODBC CONNECTOR GIVES ERROR "INVALID STRING OR BUFFER LENGTH" WHILE CONNECTING TO SYBASE IQ USING SQL ANYWHERE DRIVERS

 

APAR status

  • Closed as program error.

Error description

  • Title: ODBC Connector gives error "Invalid string or buffer
    length" while connecting to SQL Anywhere drivers
    
    Description:
    Cannot connect to SQL Anywhere database using ODBC Connector
    because of error "ODBC Function "SQLBindCol(2)" reported
    SQLSTATE = HY090: Native Error Code = 0: Msg = [Sybase][ODBC
    Driver]Invalid string or buffer length"
    In the ODBC trace file ODBC Connector is sending ODD buffer
    value to SQLBindCol.
    

Local fix

Problem summary

  • When ODBC Connector connects to SQL Anywhere database following
    error message appears "ODBC Function "SQLBindCol(2)" reported
    SQLSTATE = HY090: Native Error Code = 0: Msg = [Sybase][ODBC
    Driver]Invalid string or buffer length".
    
    This happens because ODBC Connector sends ODD integer value for
    SQLBindCol buffer length parameter.
    

Problem conclusion

  • Now sending only Even value for buffer length.
    

Temporary fix

Comments

APAR Information

  • APAR number

    JR39064

  • Reported component name

    INFO SRVR FASTT

  • Reported component ID

    5724Q36FT

  • Reported release

    810

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-03-07

  • Closed date

    2011-03-28

  • Last modified date

    2011-12-22

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    INFO SRVR FASTT

  • Fixed component ID

    5724Q36FT

Applicable component levels

  • R810 PSY

       UP

  • R811 PSY

       UP

  • R812 PSY

       UP

  • R850 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud \u0026 Data Platform"},"Product":{"code":"SSX3EG","label":"InfoSphere FastTrack"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.1"}]

Document Information

Modified date: