IBM Support

JR38661: SQA STAGE CRASHES WITH THE FOLLOWING SQA_3,0: INPUT 0 REACHED EO BUT THE OPERATOR LOGIC DID NOT

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • SQA stage crashes with the following message:
    SQA_3,0: Input 0 reached EOF but the operator logic did not
    designate another input to process via setActiveInput()
    or advanceToNextInput(), as is required in eSpecificInput mode.
    
    Engineering discovered that there are two PX problems and in
    one in the QS SQA operator.  The two PX problems created a
    situation that the QS operator was unable to handle.  For this
    particular SQA issue, we can get by only fixing the QS SQA
    operator ie make it handle the issues without failing.
    

Local fix

  • N/A
    

Problem summary

  • If a job containing an SQA stage detects composition sets with
    large numbers of records in the standardized data it processes,
    it can fail under certain circumstances with the following error
    message:
    
    "Input 0 reached EOF but the operator logic did not designate
    another input to process via setActiveInput()\nor
    advanceToNextInput(), as is required in eSpecificInput mode."
    

Problem conclusion

  • Engineering discovered that there are two PX problems and in
    one in the QS SQA operator.  The two PX problems created a
    situation that the QS operator was unable to handle.  For this
    particular SQA issue, we can get by only fixing the QS SQA
    operator ie make it handle the issues without failing.
    

Temporary fix

Comments

APAR Information

  • APAR number

    JR38661

  • Reported component name

    WIS QUALITYSTAG

  • Reported component ID

    5724Q36QS

  • Reported release

    850

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-01-14

  • Closed date

    2011-01-31

  • Last modified date

    2011-01-31

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WIS QUALITYSTAG

  • Fixed component ID

    5724Q36QS

Applicable component levels

  • R850 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVSBF","label":"InfoSphere QualityStage"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.5","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: