A fix is available
APAR status
Closed as program error.
Error description
Getting error message "Error calling subroutine DSR_LOG (action=3) Check DataStage is setup correctly in project XXX (subroutine failed to complete successfully (30107))" when navigating in the Performance Analysis Windows.
Local fix
Problem summary
**************************************************************** USERS AFFECTED: Users of Performance Analysis from DataStage Director. **************************************************************** PROBLEM DESCRIPTION: Error messages are shown when Performance Analysis is launched from a Job Log view in the DataStage Director. **************************************************************** RECOMMENDATION: Install patch JR38589 ****************************************************************
Problem conclusion
Code was changed to re-attach to relevant job after Performance Analysis is finished, and to disable Director auto-update while Performance Analysis is active.
Temporary fix
Comments
APAR Information
APAR number
JR38589
Reported component name
WIS DATASTAGE
Reported component ID
5724Q36DS
Reported release
810
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-12-31
Closed date
2011-01-13
Last modified date
2011-07-13
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WIS DATASTAGE
Fixed component ID
5724Q36DS
Applicable component levels
R810 PSY
UP