A fix is available
APAR status
Closed as new function.
Error description
The new Start mode of Auto will check for the existence of log table and then use the option of restart. If the log table does not exist, then the start mode will be clean.
Local fix
Use a job parameter for Startup Mode. Design a job sequence with a routine to check for the existence of the log tables and set the job parameter accordingly. Clean - log table does not exists. Restart - log table does exists.
Problem summary
A new option for the Start mode was added called, "auto". If a job stops prematurely, the job automatically restarts if any row entry exists in the log. To enable this option, select "auto" for the Start mode. DETAILS: Teradata Connector supports clean and restart as start modes. This requirement automatically takes care about switching on to the appropriate property depending on LOG table in the database.
Problem conclusion
RESOLUTION: There will be a new option 'auto' for start mode. This is added along with 'clean' and 'restart'. Teradata Connector will check if the job is aborted prematurely by verifying the log table and if any row entry exists it restarts with restart mode rather than clean mode.
Temporary fix
Comments
APAR Information
APAR number
JR38449
Reported component name
WIS DATASTAGE
Reported component ID
5724Q36DS
Reported release
810
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-12-10
Closed date
2011-11-22
Last modified date
2011-11-22
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WIS DATASTAGE
Fixed component ID
5724Q36DS
Applicable component levels
R810 PSY
UP