IBM Support

JR37709: RESULT OF JOB REPORT IS NOT CORRECT. A JOB WITH ONE INPUT LINK TO TRANSFORMER STAGE SHOWS TWO INPUT LINKS IN A GENERATED REPORT

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • A job has only one input link to a transformer stage but the
    report of the job show two input links to a transformer stage.
    (Basically a transformer stage should not have two input links.)
    

Local fix

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    DataStage users using Job Reporting / Parallel or Server job
    types
    ****************************************************************
    PROBLEM DESCRIPTION:
    A problem was discovered where job reporting listed incorrect
    input or output links in generated reports for a given stage.
    
    This only happened when there was a significant number of links
    (say nine or more) per stage, and whilst the original problem
    was discovered with a Transformer stage, any stage could
    potentially have the problem.
    ****************************************************************
    RECOMMENDATION:
    Install patch patch_JR37709_client_windows_8100-1
    ****************************************************************
    

Problem conclusion

  • The default stylesheet (XSL) was incorrectly matching the wrong
    internal link identifiers - this has been corrected such that
    the entire string has to matched before being included in the
    input/output link sections of the report for a given stage.
    

Temporary fix

Comments

APAR Information

  • APAR number

    JR37709

  • Reported component name

    WIS DATASTAGE

  • Reported component ID

    5724Q36DS

  • Reported release

    810

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-09-08

  • Closed date

    2010-09-22

  • Last modified date

    2011-08-17

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WIS DATASTAGE

  • Fixed component ID

    5724Q36DS

Applicable component levels

  • R810 PSN

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSEF","label":"IBM InfoSphere DataStage"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.1","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
17 August 2011