JR37533: IS 8.1 & 64 BIT DS, DEVICE NUMBERS FOR DIFFERENT FILE SYSTEMS ARE THE SAME CAUSING FILE HEADER CORRUPTION

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Information Server 8.1 on AIX 64 bit has an issue where it is
    using the smae device number for different file systems. The
    device number should be unique for each filesystem. This is
    causing file header corruption.  Since 2 files can be open in
    T30 witht he same device and inode number, when the last file is
    closed, it's header is written out to BOTH files causing header
    corruption of one of the files.
    

Local fix

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    Corruption of DataStage dynamic files can occur with versions
    8.1 and 8.1 fix pack 1 on AIX and Solaris.
    ****************************************************************
    PROBLEM DESCRIPTION:
    Corruption of DataStage dynamic files can occur in the following
    environment with versions 8.1 and 8.1 fix pack 1 on AIX and
    Solaris.  When projects are located on multiple drives in which
    the device minor number is identical, the possibility exists
    for corruption if two dynamic files with the same inode number
    in different projects are opened around the same time.
    ****************************************************************
    RECOMMENDATION:
    Patch available for 8.1.0.1 AIX.
    ****************************************************************
    

Problem conclusion

  • Fixed assignment of device number used by DataStage server
    engine on 64 bit AIX and Solaris.
    

Temporary fix

Comments

APAR Information

  • APAR number

    JR37533

  • Reported component name

    INFO SRVR PLATF

  • Reported component ID

    5724Q3612

  • Reported release

    810

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-08-18

  • Closed date

    2010-09-13

  • Last modified date

    2010-09-13

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • SERVER
    

Fix information

  • Fixed component name

    INFO SRVR PLATF

  • Fixed component ID

    5724Q3612

Applicable component levels

  • R810 PSN

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSZJPZ","label":"IBM InfoSphere Information Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.1","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]