IBM Support

JR36746: ERROR UNKNOWN ERROR READING RECORD SCHEMA

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Error "Unknown error reading record schema" when using Dataset
    Management tool with user does not have write permission.
    

Local fix

  • has to provide the write permission
    
    This fix is included in 8.0.1 fixpack 3
    

Problem summary

  • Mechanism for DataSet management requires write access to a
    temporary location in order to write script files.
    

Problem conclusion

  • If the preferred project based location is not writeable then
    use either the location defined by APT_VIEWDATA_TEMP_DIR or if
    not specified then the temporary directory defined by the UVTEMP
    setting in the uvconfig file.
    

Temporary fix

Comments

APAR Information

  • APAR number

    JR36746

  • Reported component name

    WIS DATASTAGE

  • Reported component ID

    5724Q36DS

  • Reported release

    752

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-06-02

  • Closed date

    2010-06-07

  • Last modified date

    2010-12-09

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WIS DATASTAGE

  • Fixed component ID

    5724Q36DS

Applicable component levels

  • R752 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSEF","label":"InfoSphere DataStage"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.5.2","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
12 October 2021