A fix is available
APAR status
Closed as program error.
Error description
DataStage CommonConnectors should support re-try logic when DB connection is dropped. This is to support WISD/RTI/RealTime jobs which run 24/7 and hold persistent connections to source/target databases
Local fix
Problem summary
Add the ability to reconnect and disconnect functions. Reconnect function - If a connection fails, then an attempt will be made to re-establish the connection. Disconnect function - An 'inactivity timeout' can be specified with results in a connection being disconnected after it has been inactive for a given time. When the connection is subsequently required, then the connection is re-established.
Problem conclusion
Apply patch JR36655 https://www-304.ibm.com/support/docview.wss?uid=swg21495957
Temporary fix
Comments
APAR Information
APAR number
JR36655
Reported component name
WIS DATASTAGE
Reported component ID
5724Q36DS
Reported release
810
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-05-19
Closed date
2011-09-06
Last modified date
2011-09-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WIS DATASTAGE
Fixed component ID
5724Q36DS
Applicable component levels
R810 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSEF","label":"InfoSphere DataStage"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.1","Line of Business":{"code":"LOB10","label":"Data and AI"}}]