IBM Support

JR35052: RUNTIME SCHEMA OVERRIDES DESIGN TIME SCHEMA, EVEN WITH RCP OFF

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as requirement.

Error description

  • the teble definition entered at design time gets overridden at
    runtime by the result of the select: if you are selecting all
    the fields from a source table, all the fields are passed to the
    output link even though the actual output link table definition
    doesn't contain all of the fields. This happens with RCP off,
    which seems to be unexpected behaviour.
    

Local fix

Problem summary

Problem conclusion

Temporary fix

Comments

  • Enhanced Teradata Connector not to propagate all columns in the
    actual database table when "select *" is specified by the user
    as select statement but "Runtime Column Propagation(RCP)" is
    off.
    

APAR Information

  • APAR number

    JR35052

  • Reported component name

    WIS DATASTAGE

  • Reported component ID

    5724Q36DS

  • Reported release

    810

  • Status

    CLOSED REQ

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-12-07

  • Closed date

    2009-12-21

  • Last modified date

    2009-12-21

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSEF","label":"InfoSphere DataStage"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.1","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: