A fix is available
APAR status
Closed as program error.
Error description
IS 8.0.1 fixpack1 on AIX Warning Message:: lkp_po_nbr: When checking operator: On output data set 0: When binding output interface field "gl_cmp_key" to field "gl_cmp_key": Converting a nullable source to a non-nullable result; a fatal runtime error could occur; use the modify operator to specify a value to which the null should be converted. Reviewed the job design. The source gl_cmp_key and target gl_cmp_key are both defined as not null. The warning message seems to be wrong.
Local fix
This fix is included in 8.0.1 fix pack 3
Problem summary
**************************************************************** USERS AFFECTED: ODBC EE users are affected **************************************************************** PROBLEM DESCRIPTION: Warning message generated by lookup stage: Converting a nullable source to a non-nullable result. **************************************************************** RECOMMENDATION: Upgrade to IS 8.1 ****************************************************************
Problem conclusion
Fixed in 8.1 and later versions.
Temporary fix
Comments
APAR Information
APAR number
JR34851
Reported component name
WIS DATASTAGE
Reported component ID
5724Q36DS
Reported release
810
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-11-16
Closed date
2010-04-06
Last modified date
2010-12-09
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WIS DATASTAGE
Fixed component ID
5724Q36DS
Applicable component levels
R810 PSN
UP