JR34700: SYBASE OC STAGE DOESNT SUPPORT UNSIGNED INTEGER AND UNSIGNED TINYINT

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Sybase OC stage didn't support unsigned integer and unsigned
    tinyint datatypes
    

Local fix

  • This fix is included in 8.0.1 fix pack 3
    

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    Information Server 8.0.1 on Sun fixpack1 .Sybase IQ v 12.7
    ****************************************************************
    PROBLEM DESCRIPTION:
    Sybase_OC stage error Field type must be either an int8,
    int16, uint16, or int32 in order to call
    setOutputFieldAsInteger() for field '0' in outputDS '0'.
    ****************************************************************
    

Problem conclusion

  • The following functionalities are supported now:
    
    1. INTEGER (-2147483648 and 2147483647)
    2. SMALLINT (-32768 and 32767)
    3. TINYINT (0 to 255) and we have to mention unsigned in DS.
    
    Patch can be delivered to customer.
    

Temporary fix

Comments

APAR Information

  • APAR number

    JR34700

  • Reported component name

    WIS DATASTAGE

  • Reported component ID

    5724Q36DS

  • Reported release

    801

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-10-28

  • Closed date

    2011-12-21

  • Last modified date

    2012-04-10

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WIS DATASTAGE

  • Fixed component ID

    5724Q36DS

Applicable component levels

  • R801 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSEF","label":"InfoSphere DataStage"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.0.1","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
12 October 2021