APAR status
Closed as program error.
Error description
Websphere HostOnDemand ---------------------- Ehllapi API call QuerySessionList stops returning the valid number of sessions and just returns 0. Test shows that it stops returning valid count after 26 API calls.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Ehllapi users of pcsapi API * **************************************************************** * PROBLEM DESCRIPTION: Using PCSAPI application from a MACRO * * or running a PCSAPI application * * repeatedly, after some time PCSAPI api * * call QuerySessionList fails to return * * a valid return code. * **************************************************************** * RECOMMENDATION: * **************************************************************** EHLLAPI bridge manages PCSAPI with control blocks and it has 26 of these blocks. It allocates one control block to each PCSAPI application. However it is not properly cleaning up when the application gets closed. After all 26 control blocks are exhausted, then subsequent PCSAPI applications no longer work as expected.
Problem conclusion
EHLLAPI bridge code is modified so that it cleans up PCSAPI control block properly during detach processing.
Temporary fix
Comments
APAR Information
APAR number
OA25456
Reported component name
HOD MVS
Reported component ID
5733A5900
Reported release
A00
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2008-06-10
Closed date
2008-06-20
Last modified date
2015-05-14
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
SYNCHLLA
Fix information
Fixed component name
HOD MVS
Fixed component ID
5733A5900
Applicable component levels
RA00 PSY
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSS9FA","label":"IBM Host On-Demand"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A.0","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: