IBM Support

IC56855: HATS COLUMN IS NOT CALCULATED CORRECTLY FOR DBCS FIELDS FOR RCP

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When using HATS RCP to customize a screen the OIA row/column is
    not calculated correctly for a DBCS field.  If the customer uses
    the arrow keys to advance to the right 2 spaces the cursor
    column only increases by 1.  For example the cursor is
    currently in a row/col 10/51 (the start of a DBCS field) the OIA
    will contain the correct position, but after tthe user advances
    by moving the arrow key 2 positions to the right the
    OIA will have a position of 10/52 instead of 10/53 as expected.
    

Local fix

  • Not available
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All HATS RCP DBCS users                      *
    ****************************************************************
    * PROBLEM DESCRIPTION: When the cursor is moved 2 spaces       *
    *                      within a DBCS field using the arrow     *
    *                      keys the OIA only increases by 1.       *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    To determine the OIA position special calculations need to be
    done when the cursor is within a DBCS field.  This calculation
    however, was only being done for input fields
    

Problem conclusion

  • Code was added so that whenever the cursor is in a DBCS field
    (label) or DBCS link the proper calculation will be performed.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC56855

  • Reported component name

    HATS MULTI

  • Reported component ID

    5724L0200

  • Reported release

    700

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2008-06-18

  • Closed date

    2008-08-07

  • Last modified date

    2008-08-07

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • SWTELEME
    

Fix information

  • Fixed component name

    HATS MULTI

  • Fixed component ID

    5724L0200

Applicable component levels

  • R700 PSY

       UP

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSXKAY-2","label":"Rational Host Access Transformation Services"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.0","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]