IBM Support

PK57055: CPU SPIKES DURING SYNDICATION ON WINDOWS OS

 

APAR status

  • Closed as program error.

Error description

  • At the end of the syndication run the CPU was found to spike for
    a couple of minutes before settling down and the same cycle
    would repeat each time syndication run. The following thread was
    found to be the culprit :
    
    
    3XMTHREADINFO      "WorkManager.wpsDefaultWorkManager : 21"
    (TID:0x10B529C0, sys_thread_t:0x61BC0E08, state:R, native
    ID:0xE6C)
    prio=5
    4XESTACKTRACE          at java.Io.WinNTFileSystem.delete(Native
    Method)
    4XESTACKTRACE          at java.Io.File.delete(File.java(Compiled
    Code))
    4XESTACKTRACE          at
    com.aptrix.util.FileUtils.deleteDir(FileUtils.java(Compiled
    Code))
    4XESTACKTRACE          at
    com.aptrix.deployment.subscriber.PlutoSubscriberInterface.proces
    sPackage
    (PlutoSubscriberInterface.java:247)
    4XESTACKTRACE          at
    com.aptrix.syndication.business.subscriber.SubscriberTaskManager
    .process
    Update(SubscriberTaskManager.java:148)
    4XESTACKTRACE          at
    com.aptrix.syndication.business.subscriber.SubscriberTaskManager
    $UpdateT
    ask.doManagedWork(SubscriberTaskManager.java:109)
    4XESTACKTRACE          at
    com.aptrix.syndication.business.TaskManager$ManagedTask.run(Task
    Manager.
    java:839)
    
    
    It was determined that a file input stream was opened by WCM
    which was not closed before attempting a file delete and this
    was responsible for the CPU spikes. It needs to be noted that
    this is a Windows specific problem since file locking works
    differently on UNIX and this behaviour would not be seen there.
    

Local fix

  • No workaround is available.
    

Problem summary

  • pmr closed
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    PK57055

  • Reported component name

    WRKPLC WEB CON

  • Reported component ID

    5724I2900

  • Reported release

    60A

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2007-11-26

  • Closed date

    2007-12-05

  • Last modified date

    2008-02-22

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WRKPLC WEB CON

  • Fixed component ID

    5724I2900

Applicable component levels

  • R60A PSY

       UP

[{"Business Unit":{"code":null,"label":null},"Product":{"code":"SUPPORT","label":"IBM Worldwide Support"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.0.0.1","Edition":"","Line of Business":{"code":null,"label":null}}]

Document Information

Modified date: