IBM Support

PK53830: VIEW REFERENCES COMMAND CAUSES WCM AUTHORING PORTLET TO FAIL AND SHOW BLANK WHEN VIEWING REFERENCES TO AUTHORING TEMPLATE

 

APAR status

  • Closed as program error.

Error description

  • View References command causes WCM Authoring portlet to fail and
    show blank when viewing references to authoring template
    
    This is because ReferenceLineage.isAuthoringTemplatePrototype
    can throw Null Pointer Exception such as
    
    [9/6/07 10:35:30:609 PDT] 0000004b AbstractComma E   <Null
    Message>
                                     java.lang.NullPointerException
     at
    com.ibm.workplace.wcm.services.reference.ReferenceLineage.isAuth
    oringTem
    platePrototype(ReferenceLineage.java:215)
     at
    com.ibm.workplace.wcm.services.reference.ReferenceLineage.<init>
    (Referen
    ceLineage.java:138)
     at
    com.ibm.workplace.wcm.services.reference.References.createContro
    llableRe
    ference(References.java:430)
     at
    com.ibm.workplace.wcm.services.reference.References.populateRefe
    rences(R
    eferences.java:335)
     at
    com.ibm.workplace.wcm.services.reference.References.<init>(Refer
    ences.ja
    va:120)
    

Local fix

Problem summary

  • Users Affected: Users who view the references from some WCM
    Authoring Templates
    Problem Description: When viewing the references from WCM
    Authoring template, the WCM Authoring UI would render blank, and
    in the SystemOut.log file, a NullPointerException would be
    encountered
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    PK53830

  • Reported component name

    WRKPLC WEB CON

  • Reported component ID

    5724I2900

  • Reported release

    60E

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2007-10-01

  • Closed date

    2007-10-09

  • Last modified date

    2008-02-22

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WRKPLC WEB CON

  • Fixed component ID

    5724I2900

Applicable component levels

  • R601 PSY

       UP

  • R60D PSY

       UP

  • R60E PSY

       UP