A fix is available
APAR status
Closed as program error.
Error description
Customer is using SNA/LLC2 printer session with PCOM 6.0 on Windows 7 operating system. Customer's VSE CICS host application is restarted every day at midnight. In the morning, customer cannot get print jobs. The workaround is to restart SNA node each morning.
Local fix
Stop and restart the SNA node each morning.
Problem summary
**************************************************************** * USERS AFFECTED: All users of SNA LLC2 3270 host printer * * sessions * **************************************************************** * PROBLEM DESCRIPTION: When z/VSE CICS host application is * * restarted the user cannot get print * * jobs to the PCOM printer session. * **************************************************************** * RECOMMENDATION: * **************************************************************** If a SNA printer is connected over an LLC2 link and it is reset by the receipt of DACTLU/ACTLU then if the printer is reconnected to the server before the ACTLU is received, VTAM may fail to restart the SNA session (no BIND is issued).
Problem conclusion
The problem is caused by the ACTLU RSP issued by PCOMM incorrectly indicating that the LU-LU session is already active. APPN.SYS has been changed to correct this parameter. This problem was introduced through previous APAR JR44768. Fix scheduled for PCOM 6.0.11 Refresh Pack
Temporary fix
Comments
APAR Information
APAR number
JR51178
Reported component name
COMM SERV NT 6.
Reported component ID
5639F2503
Reported release
640
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-09-02
Closed date
2014-09-02
Last modified date
2014-09-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
APPN
Fix information
Fixed component name
COMM SERV NT 6.
Fixed component ID
5639F2503
Applicable component levels
R640 PSY
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSHQNF","label":"Communications Server for Windows"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"640","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
16 October 2021