A fix is available
APAR status
Closed as program error.
Error description
A remote VTAM host has fixed pacing window size of 1. As the VTAM attempts to send data which needs more than 1 RU to complete it requests another pacing window to complete its transfer with a pacing indicator. CS/AIX sends an IPR with a status request (SR) with RASAP set. The remote VTAM host responds with a status with the Received Sequence Number (RSN) set to our BSN before the IPR, indicating that the remote host never received the IPR. However, the session continues to hang as CS/AIX never attempts to retransmit the IPR packet.
Local fix
Problem summary
USERS AFFECTED: All users of HPR PROBLEM SUMMARY: Directly connected HPR/IP connection can hang up if packets are lost in both directions in quick succession and there is no other activity on the connection to drive retries. The gap detected packet from the mainframe was dropped in the network.
Problem conclusion
Code has been changed to restart the short request timer when a status packet is received which has an implicit gap detected, i.e. the partner system indicates that it has not seen the last system sequence number transmitted but has not reported the gap detected yet (it is waiting for the refifo timer to expire).
Temporary fix
sna_v5router64
Comments
APAR Information
APAR number
JR49688
Reported component name
COMM SERV NT 6.
Reported component ID
5639F2503
Reported release
613
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-03-20
Closed date
2014-03-20
Last modified date
2014-03-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
COMM SERV NT 6.
Fixed component ID
5639F2503
Applicable component levels