A fix is available
APAR status
Closed as program error.
Error description
DLUR / DLUS session hangs PSEST after recycle of target application. When target Application is restarted, in this case CICS, a new BIND request is sent from the DLUS but no response from DLUR (CS/Linux).
Local fix
contact Level/2 support for availability of efix.
Problem summary
* USERS AFFECTED: ALL TN3270 users. * * PROBLEM DESCRIPTION: * Following CICS reset some TN3270 sessions to internal DLUR * LUs could not be re-established under stress. BINDs are not * responded to. Session hangs in VTAM 'PSEST'. The users must * issue the VTAM Vary Inact/Act command to recover from the * hang. * * PROBLEM SUMMARY: * During session termination, If the UNBIND is received before * the DACTLU AND the the DACTLU is received before the UNBIND * response can be sent to the mainframe (while it is queued to * the tnserver component) then CS/Linux fails to respond to * the UNBIND. If the mainframe reuses that independent LFSID * the subsequent BIND is not responded to (the application * cannot reconnect). Thus the new session will hang 'PSEST'. ****************************************************************
Problem conclusion
SNAPIXR/Driver.o code has been changed to correctly send the UNBIND response when DACTLU is received for a DLUR LU.
Temporary fix
efix available - contact Level/2.
Comments
APAR Information
APAR number
JR35280
Reported component name
COMM SERV NT 6.
Reported component ID
5639F2503
Reported release
613
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-01-06
Closed date
2010-01-06
Last modified date
2010-01-06
APAR is sysrouted FROM one or more of the following:
LI73892
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
COMM SERV NT 6.
Fixed component ID
5639F2503
Applicable component levels
R613 PSY
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSHQNF","label":"Communications Server for Windows"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"613","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: