This article shows you how to boot from SAS storage (in this case, the IBM System Storage DS3200) using the IBM BladeCenter-H and x86-based BladeCenter HS21 and LS21 servers. (For BladeCenter-E, check the blade compatibility matrix listed below in the Resources section to see if your environment is supported.) You will also see how to enable multipathing in Linux. Multipathing, or multipath I/O, is a fault-tolerance and performance enhancement technique where more than one physical path exists between the CPU and its mass storage devices. Simple examples are a SCSI disk connected to two SCSI controllers on the same computer or a disk connected to two Fibre Channel ports.
The major advantage of using external storage only is the improved availability of the server. Even though you can configure several different RAID levels using local disks within the blade only, you must shut down the system to replace a defective drive. Using external storage and hot-swap drives, you can replace defective drives without interrupting services. Recently, IBM announced blade servers, the BladeCenter HS12 and JS12 servers, with support for hot-swap SAS drives, but both are uniprocessor machines only.
Here are the six steps:
- Prepare the BladeCenter server and collect information on SAS modules and the DS3200.
- Prepare the storage subsystem.
- Configure the SAS BIOS.
- Install the operating system.
- Enable multipathing.
- Extend the file system with additional LUNs.
Step 1: Prepare BladeCenter server and collect information
Make sure that the SAS Switching Modules are installed correctly and connected to both DS3200 controllers. You should assume that controller A (left side when looking from the back) is connected to the SAS switch in bay 3 and controller B is connected to the SAS switch in bay 4. It doesn't matter into which port the cables are plugged and as long as you don't change the default zoning in the BladeCenter Management Module, each blade has access to all external ports.
By default, all external ports are disabled. You can enable them in two ways -- via Web or command-line interface.
Via Web interface. Login to the Web interface of your Management Module and click on Admin/Power/Restart in the I/O Module section on the left. Select the third I/O module, enable the external ports, and click on the Save button on the right.
Figure 1. Enable external ports
Via command-line interface. Login via telnet or SSH to your Management Module. Issue the following command
Listing 1. Enable external switch ports
system> ifconfig -ep enabled -T switch[3] system> ifconfig -ep enabled -T switch[4] |
to enable external ports on switch bay 3 and 4, the two SAS switches.
To map a storage partition to the blade, you need the WWN (world wide name) of the SAS daughter card. It uniquely defines the interface in a SAS domain. Collect the WWN either through the Web or the command line.
Via Web interface. In the Management Module Web interface click on Hardware VPD on the left pane.
Figure 2. Collecting the SAS WWN
Via command-line interface. Login via telnet or SSH to your
Management Module. You can list the available blades with a
list -l 2. To include installed daughter cards
in your list, issue:
Listing 2. Get detailed inventory information
system> list -l 3 |
Collect the WWN with the info command on the
daughter card of your blade slot (in this example slot 4).
Listing 3. Get SAS WWN
system> info -T blade[4]:exp[1] Manufacturer: LSI (Not Available) Manufacturer ID: 20301 Product ID: 118 Mach type/model: SAS Expansion Option Mach serial number: Not Available Manuf date: 02/08 Hardware rev: 3 Part no.: 39Y9187 FRU no.: 39Y9188 FRU serial no.: YK105481E006 CLEI: Not Available SAS ID 1: 50:00:62:b0:00:0b:26:24 SAS ID 2: 50:00:62:b0:00:0b:26:25 SAS ID 3: Not Available SAS ID 4: Not Available SAS ID 5: Not Available SAS ID 6: Not Available SAS ID 7: Not Available SAS ID 8: Not Available MAC Address 1: Not Available MAC Address 2: Not Available MAC Address 3: Not Available MAC Address 4: Not Available MAC Address 5: Not Available MAC Address 6: Not Available MAC Address 7: Not Available MAC Address 8: Not Available |
SAS ID 1 and SAS ID 2 show the WWN of port 1 (mapped to switch bay 3) and port 2 (mapped to switch bay 4).
Step 2: Prepare storage subsystem
Define storage units and map as a LUN to the blade. (A logical unit number is simply the number assigned to a logical unit. A logical unit is a SCSI protocol entity, the only one which may be addressed by the actual I/O operations.) You can use either the DS3000 Storage Manager or the DS4000 Storage Manager Software. Initial configuration is done via the Configure tab; changes go via the Modify tab.
Figure 3. DS3000 Storage Manager
In the Storage Manager, Configure Host Access (Manual) lets you define the blade and associate the two WWNs of the SAS daughter card with the blade. Make sure to select LNXCLVMWARE as the host type. This disables AVT (Automatic Volume Transfer) and is required when using the RDAC driver under Linux.
Now allocate some storage for your blade with the Create Logical Drives menu. After that, map the logical drive to a blade with the obvious Create Host-to-Logical Drive Mappings menu. Make sure to map as LUN 0 (and don't introduce any "holes" in the numbering -- some environments stop scanning after finding an unused number).
To allow for a clean install to and boot from external SAS storage, you need to ensure the correct settings in the blade BIOS as well as in the SAS daughter card BIOS. Recent releases of x86 blades (later than mid 2008) work correctly right out of the box; earlier ones might need some changes.
Verify in the LSI configuration utility that the daughter card is enabled and included in the boot list, preferably as the first boot device. SAS1064 is the daughter card, SAS1064E the onboard controller for this blade.
Figure 4. SAS BIOS settings
Also, make sure that the daughter card properties have a Boot Support value of Enabled BIOS & OS and that the BIOS scans for all LUNs. You can verify this by choosing Advanced Adapter Properties then Advanced Device Properties. If you're unsure, restore the default settings.
In the blade BIOS, make sure you haven't disabled the daughter card slot.
Figure 5: Blade BIOS settings
Depending on the preferred path of your logical unit (controller A
or B), you may either set hd0 or
hd1 as the blade's first boot device. If you
set it on the management module (like this)
Listing 4. Set boot list for blade in slot X
system> bootseq hd0 hd1 -T blade[X] |
and you get an error
I9990301 Disk failure or disk reset failed then
you have to switch boot sequence and make hd1
the first boot device. In our setup, controller A goes to I/O bay 3
which maps to hd0. Controller B connects
to I/O bay 4 and maps to hd1.
When installing the Red Hat Enterprise Linux 5.2 operating system, the
installer will see two devices called /dev/sda
and /dev/sdb. Even though it actually is the
same disk space, the installer isn't aware of the redundancy aspect of the
path and thus shows the same LUN twice. This doesn't in any way prevent
your system from working correctly since you install to
/dev/sda only. You will see error messages for
/dev/sdb which you can safely ignore by
pressing cancel.
Figure 6. OS installation error
After installation finished, you get I/O errors for
/dev/sdb. Check dmesg or have a look into
/var/log/messages. The only way to get rid of those error messages is to
install a multipath driver.
Listing 5. I/O errors due to missing multipath driver
Jul 1 19:47:26 localhost kernel: Buffer I/O error on device sdb, logical block 13107184 Jul 1 19:47:26 localhost kernel: end_request: I/O error, dev sdb, sector 104857472 Jul 1 19:47:26 localhost kernel: Buffer I/O error on device sdb, logical block 13107184 Jul 1 19:47:27 localhost kernel: end_request: I/O error, dev sdb, sector 0 Jul 1 19:47:27 localhost kernel: Buffer I/O error on device sdb, logical block 0 Jul 1 19:47:27 localhost kernel: Buffer I/O error on device sdb, logical block 1 Jul 1 19:47:27 localhost kernel: Buffer I/O error on device sdb, logical block 2 Jul 1 19:47:27 localhost kernel: Buffer I/O error on device sdb, logical block 3 Jul 1 19:47:27 localhost kernel: end_request: I/O error, dev sdb, sector 0 Jul 1 19:47:28 localhost kernel: end_request: I/O error, dev sdb, sector 2 |
There are two ways to enable multipathing under Linux -- using the official RDAC driver from IBM/LSI and the open source multipath tools of the device-mapper. This example uses the RDAC driver that is available on the LSI Web site.
Make sure to have the following additional packages installed:
- gcc,
- glibc-devel,
- kernel-headers,
- glibc-headers,
- libgomp, and
- kernel-devel or kernel-xen-devel if using the Xenified kernel.
Download the RDAC source from the LSI Web site and compile in /usr/src
with the usual
make && make install.
At the end, you will get messages like in Listing 6.
Listing 6. LSI RDAC driver installation
Checking Host Adapter Configuration...
Detected 2 LSI Host Adapter Port(s) on the system
Please wait while we modify the system configuration files.
Your kernel version is 2.6.18-92.el5xen
Preparing to install MPP driver against this kernel version...
Generating module dependencies...
Creating new MPP initrd image...
You must now edit your boot loader configuration file, /boot/grub/menu.lst, to
add a new boot menu, which uses mpp-2.6.18-92.el5xen.img as the initrd image.
Now Reboot the system for MPP to take effect.
The new boot menu entry should look something like this (note that it may
vary with different system configuration):
...
title Red Hat Linux (2.6.18-92.el5xen) with MPP support
root (hd0,5)
kernel /vmlinuz-2.6.18-92.el5xen ro root=LABEL=RH9
initrd /mpp-2.6.18-92.el5xen.img
...
MPP driver package has been successfully installed on your system.
|
As the message says, edit your /boot/grub/grub.conf to use the new ramdisk. For a RHEL5.2 system running the Xen-enabled kernel, change to the following:
Listing 7. grub.conf using the multipath ramdisk
default=1
timeout=5
splashimage=(hd0,0)/grub/splash.xpm.gz
hiddenmenu
title Red Hat Enterprise Linux Server (2.6.18-92.el5xen)
root (hd0,0)
kernel /xen.gz-2.6.18-92.el5
module /vmlinuz-2.6.18-92.el5xen ro root=/dev/VolGroup00/LogVol00
module /initrd-2.6.18-92.el5xen.img
title Red Hat Enterprise Linux Server with MPP support (2.6.18-92.el5xen)
root (hd0,0)
kernel /xen.gz-2.6.18-92.el5
module /vmlinuz-2.6.18-92.el5xen ro root=/dev/VolGroup00/LogVol00
module /mpp-2.6.18-92.el5xen.img
|
mppUtil -a (Listing 8) shows all discovered
arrays, in this case only one name Infra-sas2.
Listing 8. Basic multipath information
[root@localhost ~]# mppUtil -a Hostname = localhost Domainname = (none) Time = GMT 07/01/2008 19:56:01 --------------------------------------------------------------- Info of Array Module's seen by this Host. --------------------------------------------------------------- ID WWN Name --------------------------------------------------------------- 0 600a0b80002f746e0000000047d02718 Infra-sas2 --------------------------------------------------------------- |
If you want basic LUN mapping information, issue
/opt/mpp/lsvdev:
Listing 9. Basic LUN mapping information
[root@localhost ~]# /opt/mpp/lsvdev
Array Name Lun sd device
-------------------------------------
Infra-sas2 0 -> /dev/sda
|
mppUtil -a [array name] shows details about
this array:
Listing 10. Detailed multipath information
[root@localhost ~]# mppUtil -a Infra-sas2
Hostname = localhost
Domainname = (none)
Time = GMT 07/01/2008 19:56:27
MPP Information:
----------------
ModuleName: Infra-sas2 SingleController: N
VirtualTargetID: 0x000 ScanTriggered: N
ObjectCount: 0x000 AVTEnabled: N
WWN: 600a0b80002f746e0000000047d02718 RestoreCfg: N
ModuleHandle: none Page2CSubPage: Y
FirmwareVersion: 6.30.1.xx
ScanTaskState: 0x00000000
Controller 'A' Status:
-----------------------
ControllerHandle: none ControllerPresent: Y
UTMLunExists: N Failed: N
NumberOfPaths: 1 FailoverInProg: N
ServiceMode: N
Path #1
---------
DirectoryVertex: present Present: Y
PathState: OPTIMAL
hostId: 1, targetId: 0, channelId: 0
Controller 'B' Status:
-----------------------
ControllerHandle: none ControllerPresent: Y
UTMLunExists: N Failed: N
NumberOfPaths: 1 FailoverInProg: N
ServiceMode: N
Path #1
---------
DirectoryVertex: present Present: Y
PathState: OPTIMAL
hostId: 1, targetId: 1, channelId: 0
Lun Information
---------------
Lun #0 - WWN: 600a0b8000369d3f00000775481870af
----------------
LunObject: present CurrentOwningPath: A
RemoveEligible: N BootOwningPath: A
NotConfigured: N PreferredPath: A
DevState: OPTIMAL ReportedPresent: Y
ReportedMissing: N
NeedsReservationCheck: N
TASBitSet: Y
NotReady: N
Busy: N
Quiescent: N
Controller 'A' Path
--------------------
NumLunObjects: 1 RoundRobinIndex: 1
Path #1: LunPathDevice: present
IoCount: 0
DevState: OPTIMAL
RemoveState: 0x0 StartState: 0x1 PowerState: 0x0
Controller 'B' Path
--------------------
NumLunObjects: 1 RoundRobinIndex: 0
Path #1: LunPathDevice: present
IoCount: 0
DevState: OPTIMAL
RemoveState: 0x0 StartState: 0x1 PowerState: 0x0
|
The last two sections show that currently controller A is handling
the traffic (RoundRobinIndex: 1). Both paths
are present and in an optimal state
(LUNPathDevice present,
DevState optimal).
Another way to display multipath information about all available arrays
and LUNs is by issueing an ls -lR /proc/mpp --
it lists the available controllers and all available LUNs for each array.
Details can be obtained by displaying the contents of the respective LUN
proc entries. The intermediate directory mptsas_h1c0t0 reflects the Linux
SCSI address (host, channel, target):
Listing 11. Multipath information from /proc
[root@localhost ~]# cat /proc/mpp/Infra-sas2/controllerA/mptsas_h1c0t0/LUN0
Linux MPP driver. Version:09.01.C5.19 Build:Tue Apr 1 13:30:42 CDT 2008
Lun WWN:600a0b8000369d3f00000775481870af
Physical HBA driver: mptsas
Device Scsi Address: host_no:1 channel:0 target:0 Lun:0
Queue Depth = 64
I/O Statistics:
Number of IOs:8846
Longest trip of all I/Os:1
Shortest trip of all I/Os:0
Number of occurrences of IO failed events:0
|
MPP is configured through /etc/mpp.conf. If you make any changes you have
to run mppUpdate to rebuild the ramdisk with
the new config file. A reboot is required to activate the changes.
Step 6: How to extend with additional LUNs
If you need to assign more disk space to the operating system, you can easily do this by assigning more storage units to the blade, adding them to LVM, and extending the file system over the new disk space.
But before we go onto defining new units and using them, a word on the Logical Volume Manager (LVM). LVM provides an abstraction to the underlying storage. It groups one or more physical volumes (disks) into a volume group. This volume group serves as a logical container for one or more logical volumes which show up as a SCSI device in Linux (as you can see in Figure 7).
Figure 7. Logical Volume Manager
Now let's get on with it.
Define new units in storage manager
Create new storage units with the Storage Manager tool (see step 2).
It is a two-way process to use the new storage unit(s) in Linux. You have to add them to LVM before you can increase the actual Linux file system.
Start a rescan of the SAS bus with the hot_add
utility (it is a link to mppBusRescan) to
discover newly mapped storage units:
Listing 12. Discover new LUNs
[root@localhost ~]# hot_add
Starting new devices re-scan...
scan mptsas HBA host /sys/class/scsi_host/host1...
found 1:0:0:1
found 1:0:1:1
scan mptsas HBA host /sys/class/scsi_host/host0...
no new device found
run /usr/sbin/mppUtil -s busscan...
scan mpp virtual host /sys/class/scsi_host/host3...
found 3:0:0:1->/dev/sdb
/usr/sbin/hot_add is completed.
|
Linux has found one new unit and mapped it to
/dev/sdb. Note that the new unit is
automatically managed by the multipath driver.
To prepare the unit for LVM, create a primary LVM partition (partition type 8e) spanning the whole disk:
Listing 13. Prepare the new logical unit
[root@localhost ~]# fdisk /dev/sdb Device contains neither a valid DOS partition table, nor Sun, SGI or OSF disklabel Building a new DOS disklabel. Changes will remain in memory only, until you decide to write them. After that, of course, the previous content won't be recoverable. The number of cylinders for this disk is set to 51200. There is nothing wrong with that, but this is larger than 1024, and could in certain setups cause problems with: 1) software that runs at boot time (e.g., old versions of LILO) 2) booting and partitioning software from other OSs (e.g., DOS FDISK, OS/2 FDISK) Warning: invalid flag 0x0000 of partition table 4 will be corrected by w(rite) Command (m for help): n Command action e extended p primary partition (1-4) p Partition number (1-4): 1 First cylinder (1-51200, default 1): Using default value 1 Last cylinder or +size or +sizeM or +sizeK (1-51200, default 51200): Using default value 51200 Command (m for help): t Selected partition 1 Hex code (type L to list codes): 8e Changed system type of partition 1 to 8e (Linux LVM) Command (m for help): w The partition table has been altered! Calling ioctl() to re-read partition table. Syncing disks. |
Now integrate the new unit into the existing volume group. Listing 14
shows how you can verify with vgdisplay -s
before and after the expansion:
Listing 14. Extend LVM volume group
[root@localhost ~]# vgdisplay -s "VolGroupBoot" 49.88 GB [49.88 GB used / 0 free] [root@localhost ~]# pvcreate /dev/sdb1 Physical volume "/dev/sdb1" successfully created [root@localhost ~]# vgextend VolGroupBoot /dev/sdb1 Volume group "VolGroupBoot" successfully extended [root@localhost ~]# vgdisplay -s "VolGroupBoot" 49.88 GB [49.88 GB used / 49.97 free] |
Next, increase the logical volume within this volume group. You can verify
with lvdisplay by comparing the
LV Size row:
Listing 15. Extend LVM logical volume
[root@localhost ~]# lvdisplay /dev/VolGroupBoot/LogVolSlash --- Logical volume --- LV Name /dev/VolGroupBoot/LogVolSlash VG Name VolGroupBoot LV UUID dIanEg-J6Mf-60Ec-eUKb-rgoJ-dOM0-QmjQ3Q LV Write Access read/write LV Status available # open 1 LV Size 47.94 GB Current LE 1534 Segments 1 Allocation inherit Read ahead sectors auto - currently set to 256 Block device 253:0 [root@localhost ~]# lvextend -l +100%FREE /dev/VolGroupBoot/LogVolSlash /dev/sdb1 Extending logical volume LogVolSlash to 97.91 GB Logical volume LogVolSlash successfully resized [root@localhost ~]# lvdisplay /dev/VolGroupBoot/LogVolSlash --- Logical volume --- LV Name /dev/VolGroupBoot/LogVolSlash VG Name VolGroupBoot LV UUID dIanEg-J6Mf-60Ec-eUKb-rgoJ-dOM0-QmjQ3Q LV Write Access read/write LV Status available # open 1 LV Size 97.91 GB Current LE 3133 Segments 2 Allocation inherit Read ahead sectors auto - currently set to 256 Block device 253:0 |
Now you are ready to resize your file system (takes about two minutes for 50GB on the SAS drives). If you resize your root file system, only ext3 is supported for online resizing (which means you don't have to schedule a maintenance window for the system).
Listing 16. Resize Linux file system
[root@localhost ~]# df -h
Filesystem Size Used Avail Use% Mounted on
/dev/mapper/VolGroupBoot-LogVolSlash 47G 2.3G 42G 6% /
[root@localhost ~]# resize2fs -p /dev/VolGroupBoot/LogVolSlash
resize2fs 1.39 (29-May-2006)
Filesystem at /dev/VolGroupBoot/LogVolSlash is mounted on /; on-line resizing required
Performing an on-line resize of /dev/VolGroupBoot/LogVolSlash to 25665536 (4k) blocks.
The filesystem on /dev/VolGroupBoot/LogVolSlash is now 25665536 blocks long.
[root@localhost ~]# df -h
Filesystem Size Used Avail Use% Mounted on
/dev/mapper/VolGroupBoot-LogVolSlash
95G 2.3G 88G 3% /
|
And that's it!
I've shown you how to set up a successful boot for a BladeCenter server from an SAS-controlled IBM BladeCenter Boot Disk System (DS3200) and you've also learned
- How to enable multipathing to ensure efficient fault tolerance.
- How to extend the file system to keep up with growing storage demands using the hot-add feature of the LVM.
Remember, using only external storage offers you improved availability of your blade server; in this article we focused on the benefit you get from not having to interrupt your server to replace or upgrade drives.
Learn
- Learn more about
the
IBM BladeCenter Boot Disk System,
a 2U enclosure that is specifically designed to provide boot functionality
for up to two fully loaded BladeCenter E or BladeCenter H chassis.
- Red Hat's
Device-mapper Resource Page is a
good source for the tool, including multipath bug reporting and other
documentation.
-
"IBM System Storage DS3000: Introduction and Implementation Guide"
(IBM Redbooks, December 2008) introduces
the IBM System Storage DS3000 family.
- Check
compatibility
with BladeCenter products.
- In the
developerWorks Linux zone,
find more resources for Linux developers (including developers who are
new to Linux), and scan our
most popular articles and
tutorials.
-
See all
Linux tips and
Linux tutorials on developerWorks.
-
Stay current with
developerWorks technical events and Webcasts.
Get products and technologies
- Get the
RDAC Driver Package for IBM DS3000
Storage Subsystems.
-
Order the SEK for Linux,
a two-DVD set containing the latest IBM trial software for Linux from DB2®,
Lotus®, Rational®, Tivoli®, and WebSphere®.
-
With
IBM trial software,
available for download directly from developerWorks, build your next development
project on Linux.
Discuss
-
Get involved in the
developerWorks community through blogs, forums, podcasts, and spaces.

Martin Bachmaier works as an IT Specialist in the IBM Cell/B.E. Blade development lab in Boeblingen, Germany. As part of the Open Systems Design and Development team, one of his responsibilities is the architecture and management of Linux-based infrastructures, as well as initial support for them at customer installations and development teams around the world. As such, he's always excited to help develop great solutions based on open source in today's data centers. He participated in a Redbooks residency program focused on IBM iDataPlex that produced a Redpaper, a Redbook, and a product review guide.
Comments (Undergoing maintenance)