Optimizing internal AIX storage

Principles and tools for better AIX performance

Although SAN technology has taken the limelight when it comes to storage solutions, AIX systems still need to use internal storage. Whether you have small stand-alone servers or use a full system partition with all the resources available pooled together, internal storage is the typical medium for root volume groups and other smaller file system utilization. But when these disks are not planned out well, I/O bottlenecks, inefficient space utilization, and slower performance can occur. Learn how to optimize internal storage and lay things out properly.

Christian Pruett, Senior systems administrator , Freelance

Christian Pruett is a senior UNIX systems administrator with more than 14 years of experience with AIX, Sun Solaris, Linux, and HP/UX in a wide variety of industries, including computing, agriculture, and telecommunications. He is the co-author of two IBM Redbooks on AIX, has served as a UNIX book review for O’Reilly Publishing, and has worked on several of the IBM AIX certification exams. He resides in Colorado with his wife and two children. You can reach Christian at pruettc@gmail.com.



10 January 2012

Also available in Chinese Russian

A little while ago, I needed to perform an operating system patch on an IBM® AIX® server to a more recent technology level and service pack. This server had not had any software maintenance in some time, so it was due for a tune-up. I got everything lined up for a maintenance window and started the upgrade.

As things were running, I noticed that the server became particularly slow. Although no applications were active on the system and no users were logged in, the server's performance slowed considerably. It didn't make sense, as this was a stand-alone server, not a virtualized logical partition (LPAR) with any other systems contending for CPU resources or shared infrastructure.

While performing some troubleshooting, I pulled up the server's real-time data using the topas command and noticed that the Wait column had a tremendously high value. But only one disk was causing all of the overhead—hdisk0—where the root volume group resided. I looked at the disk using the lspv –p command, and suddenly everything made sense (see Listing 1 below).

Listing 1. Results of the lspv -p command
# lspv -p hdisk0
hdisk0:
PP RANGE  STATE   REGION        LV NAME             TYPE       MOUNT POINT
  1-1     used    outer edge    hd5                 boot       N/A
  2-110   free    outer edge
111-114   used    outer middle  hd6                 paging     N/A
115-116   used    outer middle  livedump            jfs2       /var/adm/ras/livedump
117-124   used    outer middle  lg_dumplv           sysdump    N/A
125-130   used    outer middle  paging00            paging     N/A
131-136   used    outer middle  hd6                 paging     N/A
137-217   free    outer middle
218-219   used    outer middle  hd2                 jfs2       /usr
220-220   used    center        hd8                 jfs2log    N/A
221-222   used    center        hd4                 jfs2       /
223-237   used    center        hd2                 jfs2       /usr
238-240   used    center        hd9var              jfs2       /var
241-241   used    center        hd3                 jfs2       /tmp
242-242   used    center        hd1                 jfs2       /home
243-245   used    center        hd10opt             jfs2       /opt
246-246   used    center        hd11admin           jfs2       /admin
247-259   used    center        hd10opt             jfs2       /opt
260-265   used    center        hd4                 jfs2       /
266-266   used    center        hd2                 jfs2       /usr
267-279   used    center        hd9var              jfs2       /var
280-284   used    center        hd2                 jfs2       /usr
285-285   used    center        hd3                 jfs2       /tmp
286-286   used    center        hd2                 jfs2       /usr
287-317   used    center        hd1                 jfs2       /home
318-328   used    center        paging00            paging     N/A
329-425   free    inner middle
426-430   used    inner middle  hd6                 paging     N/A
431-437   free    inner middle  
438-535   free    inner edge
536-546   used    inner edge    paging01            paging     N/A

When I saw how this disk was laid out, it explained why there was an I/O bottleneck. The disk had a number of mistakes and some poor planning that caused even a simple upgrade to take considerably longer than it should have. It proved that even in today's world of storage area networks (SAN), Internet SCSI (iSCSI), and other top-tier storage solutions, even basic internal disks need to be optimized and set up properly so that modern, more robust servers can run well.

This article provides some of the basic tools and techniques that you can use to optimize internal storage on AIX servers. Using the situation I encountered as a case study, the article walks through how disks are viewed within AIX and how they interact with the Logical Volume Manager (LVM). From there, it discusses various strategies and commands for reorganizing internal disks and making them more solid, including some lower-level commands and simple shortcuts. Then, the article offers some higher-level planning ideas to prevent these situations from happening again.

Disk layout

The AIX operating system divides hard disks—also known as physical volumes (PV)—into fixed areas of space called physical partitions (PP). These PPs are all uniform in size and span from the outer edge of the disk, moving inward toward the center of the spindle. As these PVs are gathered, they become known as volume groups (VG). Within these VGs, the system creates structures called logical volumes (LV) that gather PPs into usable areas on which file systems can be created.

The PP size is fixed with the creation of the VG, and further PVs added to the VG are expected to conform the same PP size. Each PP can be assigned to only one LV at a time, and any LV must have a minimum of one PP to exist. If file systems are grown, the minimum size by which they will expand is one PP.

AIX divides PVs into five areas relative to their location on the hard disk platters themselves: outer edge, outer middle, center, inner middle, and inner edge. This division is illustrated below in Figure 1.

Figure 1. Disk layout
Diagram of AIX disk layout

Several mathematic and physics-based properties affect disk I/O, latency, and access across these five regions. Because of conservation of angular momentum, the outer edge of the disk has a faster rotational velocity than the slower inner edge—much like how kids riding a carousel at the playground will whip around much more quickly on the outside than in the middle. However, because not all the data on the disk will be written to the outer edge as a result of the limitations of the physical placement of the data, the fastest seek times for the hard disk heads will be in the center area of the disk, where the head is most likely to pass on average.

In the case of the server I was trying to patch, the data was located across the disk in an almost chaotic or random manner. But before that data could be sorted out, more considerations had to take place for how AIX manages LVs directly.


Logical Volume Manager considerations

AIX has a native tool called the Logical Volume Manager which handles the relationships among PVs, VGs, LVs, and file systems. The LVM creates the logical structures on physical media for managing data within the operating system. Relevant to disk optimization, the LVM also provides a means of customizing availability, performance, and redundancy.

The two most widely used features that LVM has to boost optimization are through mirroring and striping. LVM allows you to mirror LVs with up to three copies of the data. Here, one LP can point to one or more PPs. This way, should a hardware failure occur, the data is preserved on other physical devices. In smaller systems that use internal storage especially, it is crucial that all data be mirrored to prevent unplanned outages.

Striping places data across multiple hard disks so that multiple read and write operations can occur simultaneously across a wide number of disks. You enable striping by changing the inter-physical volume allocation policy property for each LV. By setting the policy to the minimum (the default), there is greater reliability, because no one disk failure could affect the LV. By setting the policy to the maximum, LVM stripes the data across the maximum number of disks within the VG possible, maximizing the number of I/O operations that can occur at once.

When looking at optimizing internal disks, the balance between performance and redundancy has to be kept in check. With smaller systems, there is typically not enough room to perform large-scale striping, let alone striping with redundancy through mirroring. With larger systems that have large quantities of internal hard disks, striping and mirroring can dramatically boost performance and minimize I/O wait times.


Optimizing internal disks

By combining these concepts of how AIX physically structures hard disks with how LVM can impose logical structures onto disks, I have put together several principles to help optimize internal disks:

  • Make LVs contiguous as much as possible. When file systems are strewn across a disk, the hard disk head takes longer to find any wanted data. If the LV exists in one continuous area, the seek time is minimized and the files can be found more quickly.
  • Place LVs with high I/O or sequential read or write operations on the outer edge. Because of the speed of the outer edge of the disk, LVs that need faster reads or writes with data in long sequences (like large static files or database contents) will benefit from the higher rotational velocity at the outer edge.
  • Place LVs with high activity toward the center. If you have a file system that has a great deal of reads and writes and needs quick responsiveness, because of averages, the hard disk head will most likely be near the center at any point in time. By placing those file systems in this area, there will be a higher likelihood that the head will be in that general vicinity. This configuration reduces seek time and maintains good I/O.
  • Place LVs with low usage near the inner edge. If you have any file systems that are rarely used or accessed, get them out of the way by putting them in the part of the disk with the lowest I/O speeds—near the spindle at the inner edge. For example, logical volumes that are seldom used fit well here.
  • Use only one paging space LV per disk. The purpose of paging space is to serve as a temporary place to swap pages in and out of memory to an area of physical storage, thus allowing the CPU to perform more operations and catch up on things. Defining multiple paging space LVs on the same disk defeats the purpose of trying to remedy performance shortfalls by causing more I/O, as the disk head has to go to several areas of the platters instead of just one.
  • Where possible, don't mirror paging space. Again, because the purpose of paging space is to use physical storage to offset resource shortfalls, it makes no sense to write the same set of data twice in a mirrored configuration. Instead, if two disks have two separate paging space LVs, each can address memory swapping and double the effectiveness.
  • Keep paging space sizes uniform. One last point on paging space is to keep paging space LVs as uniform as possible. If you have two 73GB internal disks and one has a 1GB paging space LV while the other one has a 4GB paging space LV, one of these two will likely experience more wear. And, depending on how the paging space was added to the server or shrunk in size, one of the LVs may become full and adversely affect the system. Plus, keeping sizes the same makes the lsps command output look a little cleaner and more accurate.
  • Keep some free space around. Although there may be some administrators out there who try to squeeze every last drop of capacity from their servers, it is always best to keep some free space on the disks. This is not just relative to having one or two large gaps in the inner or outer middle regions, but having space between the LVs in case anything needs to be grown and a little free space in the file systems themselves. If everything is pressed together, all it takes is one small chfs –a size=+1MB command to wreck LV contiguity.
  • Mirror things properly. One common mistake administrators make is to create a new file system on a mirrored VG, then forget to create a copy onto the other disk. Just because the VG is mirrored does not mean that any subsequently added LVs that support the file systems will also be mirrored. Always make sure that new LVs get a copy on a separate PV.
  • Distribute I/O load as much as possible for performance and redundancy. If you have a larger system with multiple drawers, leverage them by striping the data across sets of disk packs. And, if you choose to mirror your PVs, do it across different drawers so that if a backplane fails, redundancy is not limited to one drawer.

Tools for optimizing disks

The next step in this process is to make these principles for internal storage optimization a reality. There are several commands I employ to straighten out wayward disks and make them conform to how they should be designed.

lspv, lsvg, and lslv

The lspv, lsvg, and lslv commands are the key tools for visualizing how everything is laid out. The lspv command shows how the data is dispersed on the PVs (as shown in my earlier example). The lsvg command with the –l flag shows at a glance whether the data is mirrored and what contents are within the VG. And the lslv command should be used with the –m flag to analyze the layout for any particular LV within the five areas of the PVs, as shown here:

hd4:/
PV                COPIES        IN BAND       DISTRIBUTION
hdisk0            128:000:000   100%          000:108:020:000:000

chlv

The chlv command is typically the first command I run that changes things to optimize disks. I use it to set the intra-PV allocation policy for where LVs should be placed on the PVs, from the outer to the inner edge. This command helps in consolidating the data and making it contiguous.

migratepv

If I find that some of the LVs are not on the correct PVs, before I go into more of the reorganization, I use migratepv to shift things around between PVs by using the –l flag to move data on an LV-by-LV basis.

reorgvg

The reorgvg command is the true workhorse for optimizing internal disks. This command takes the intra-PV allocation policy for each LV and reorganizes the PV around these standards. It does its best to move the LVs into the specific areas of the disks and align the space properly. But it can take a considerable amount of time to run in some circumstances, and it may not be able to get everything perfect, which is why manual intervention may be needed.

migratelp

After LVs have been shifted around, there may be one or two pesky stuck LPs or PPs somewhere on the disk, so that a piece of /tmp winds up surrounded by most of /usr. The migratelp command can move data on an LP-by-LP basis manually to get things out of the way.

mirrorvg and mklvcopy

You use the mirrorvg and mklvcopy commands to mirror an entire VG at once (mirrorvg) or make copies of specific LVs, such as when file systems are added (mklvcopy). But, there are two tricks you can use with mirrorvg to optimize internal storage. If the intra-PV allocation policies have been set with chlv, by mirroring the volume group with a –c flag, the data will be mirrored to a fresh PV and conform to those policies along the way, laying it out cleanly. Or, if you already have a nicely optimized disk, you can use the –m flag and have the second PV laid out exactly like the first to have completely parallel reads and writes.


The results

After putting these principles in place and using the tools above, I was able to remedy my poor disk mainly through consolidating paging space, sizing file systems correctly, and putting LVs in proper places on the PV. As you can see in Listing 2 below, the disk space was used much more effectively, and I/O definitely improved.

Listing 2. Running lspv after disk optimization
# lspv -p hdisk0
hdisk0:
PP RANGE  STATE   REGION        LV NAME             TYPE       MOUNT POINT
  1-1     used    outer edge    hd5                 boot       N/A
  2-2     used    outer edge    hd8                 jfs2log    N/A
  3-110   free    outer edge
111-130   used    outer middle  hd6                 paging     N/A
131-147   used    outer middle  hd9var              jfs2       /var
148-219   free    outer middle  
220-245   used    center        hd2                 jfs2       /usr
246-252   used    center        hd1                 jfs2       /home
253-255   used    center        hd3                 jfs2       /tmp
256-270   used    center        hd10opt             jfs2       /opt        
271-328   free    center        
329-337   used    inner middle  hd4                 jfs2       /
338-437   free    inner middle  
438-440   used    inner edge    livedump            jfs2       /var/adm/ras/livedump
441-448   used    inner edge    lg_dumplv           sysdump    N/A
449-449   used    inner edge    hd11admin           jfs2       /admin
450-546   free    inner edge

With this layout, the hard disk head does not have to move too far away from the center area, I have room to grow some of the file systems, and there is less I/O wait time. By mirroring this configuration identically to a second disk, I also provided redundancy to mitigate possible failures.


Conclusion

In the old days of AIX 4.3.3 and IBM RS/6000® servers, disk optimization was necessary to make servers perform well because of the limited resources available. But even though disks today often exceed 100GB in size and 15,000 RPMs in speed and newer IBM POWER7® servers run faster and do more than any AIX servers before, this relatively simple process for optimizing internal storage can still make all the difference.

Resources

Learn

Discuss

Comments

developerWorks: Sign in

Required fields are indicated with an asterisk (*).


Need an IBM ID?
Forgot your IBM ID?


Forgot your password?
Change your password

By clicking Submit, you agree to the developerWorks terms of use.

 


The first time you sign into developerWorks, a profile is created for you. Information in your profile (your name, country/region, and company name) is displayed to the public and will accompany any content you post, unless you opt to hide your company name. You may update your IBM account at any time.

All information submitted is secure.

Choose your display name



The first time you sign in to developerWorks, a profile is created for you, so you need to choose a display name. Your display name accompanies the content you post on developerWorks.

Please choose a display name between 3-31 characters. Your display name must be unique in the developerWorks community and should not be your email address for privacy reasons.

Required fields are indicated with an asterisk (*).

(Must be between 3 – 31 characters.)

By clicking Submit, you agree to the developerWorks terms of use.

 